Development of an Imaging‐Based Method for Analyzing Voided Urine Flow Using Conventional and High‐Speed Video Cameras: A Phantom Study

AIMS: This study examined whether voided urine form could be an independent parameter to evaluate pathology of the lower urinary tract separately from conventional uroflowmetric measurements. We also evaluated a novel combined methodology of dynamically measuring the velocity and cross-sectional area (CA) of voided urine. METHODS: A male urethral phantom was connected to an electric pump, and voided water was recorded using a high-speed video camera (HSVC). The parameters of voided water form included length to the first twist (LFT), length to the scattered water (LSW), and voided water angle (VWA), which were measured in combination with conventional uroflowmetry. The velocity and CA of voided water were measured using an analysis program of fluid movement. Variations of ductal deformity were simulated using silicon tube attachments. RESULTS: Each parameter increased with pump speed apart from VWA. Flow rate did not change for any attachment except for the stricture type, for which the relative change of LFT surpassed that of LSW. The VWA results were slightly increased by urethral deformity. All results for velocity and CA increased with pump speed and were unaffected by urethral deformity under fixed water flow. CONCLUSION: LFT and LSW represent novel voided water form parameters that are separate from conventional uroflowmetric measurements, such as flow rate. Voided water velocity and CA can be non-invasively determined by the combination of uroflowmetry and a HSVC.

Authors

Institutions

Publication Details

Journal
LUTS Lower Urinary Tract Symptoms
Published
2026-07-28
DOI
https://doi.org/10.1111/luts.70084
Primary Topic
Urinary Tract Infections Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an Imaging‐Based Method for Analyzing Voided Urine Flow Using Conventional and High‐Speed Video Cameras: A Phantom Study

Tomonori Minagawa, 正博 後藤, Tetsuichi Saito, Tetsuya Imamura et al.
LUTS Lower Urinary Tract Symptoms
Urinary Tract Infections Management
article

Development of an Imaging‐Based Method for Analyzing Voided Urine Flow Using Conventional and High‐Speed Video Cameras: A Phantom Study

Tomonori Minagawa, 正博 後藤, Tetsuichi Saito, Tetsuya Imamura, Yoshiyuki Akiyama, Hiroaki Hara, Noriyuki Ogawa, Manabu Ueno
article en

Abstract

AIMS: This study examined whether voided urine form could be an independent parameter to evaluate pathology of the lower urinary tract separately from conventional uroflowmetric measurements. We also evaluated a novel combined methodology of dynamically measuring the velocity and cross-sectional area (CA) of voided urine. METHODS: A male urethral phantom was connected to an electric pump, and voided water was recorded using a high-speed video camera (HSVC). The parameters of voided water form included length to the first twist (LFT), length to the scattered water (LSW), and voided water angle (VWA), which were measured in combination with conventional uroflowmetry. The velocity and CA of voided water were measured using an analysis program of fluid movement. Variations of ductal deformity were simulated using silicon tube attachments. RESULTS: Each parameter increased with pump speed apart from VWA. Flow rate did not change for any attachment except for the stricture type, for which the relative change of LFT surpassed that of LSW. The VWA results were slightly increased by urethral deformity. All results for velocity and CA increased with pump speed and were unaffected by urethral deformity under fixed water flow. CONCLUSION: LFT and LSW represent novel voided water form parameters that are separate from conventional uroflowmetric measurements, such as flow rate. Voided water velocity and CA can be non-invasively determined by the combination of uroflowmetry and a HSVC.

LUTS Lower Urinary Tract SymptomsVol. 18(5)
Shinshu University (JP)
Clean water and sanitation
Openalex Percentile: Top 8%
Urinary Tract Infections Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.