Cochlear implant electrode insertion complication in a group of over 300 paediatric recipients

Objective: Electrode tip fold-over (TFO) represents a complication of cochlear implantation. TFO may lead to insertion trauma and malfunction of the cochlear implant (CI), often requiring re-implantation. It is mostly associated with pre-shaped CI electrodes.Methods: Our aim was to provide a systematic literature review to examine the current rate of electrode TFO with different commercially available electrode types and compare it with our clinical experience. We performed a retrospective analysis of 370 paediatric CI patients up to 19 years of age, who underwent surgery at our department between 2014 and 2024. We studied laterality, diagnostic findings that revealed a TFO, and subsequent therapeutic solutions.Results: Intraoperative plain film X-ray and neural response telemetry (NRT) were performed during surgeries. In total, 585 ears were operated (unilateral, metachronic, and synchronic bilateral implantation). Straight electrodes were used in 26.3% and pre-shaped electrodes in 73.7% of surgeries. TFO was diagnosed in 17 cases (2.8%), including 11 male (65%) and 6 female (35%) patients. Most TFO complications were caused by pre-shaped electrodes (15 out of 17). There were 14 TFOs on the right side and 3 on the left. TFO was diagnosed mostly by X-ray. NRT was not proven to be a reliable method to detect a TFO.Conclusions: According to our review of 7550 CI surgeries, TFOs were identified in 222 ears with pre-shaped electrodes (4.2% incidence) and 13 ears with straight electrodes (0.57% incidence). In our cohort, the total occurrence of TFO was 2.8%, predominantly caused by pre-shaped electrode arrays compared to straight arrays.

Authors

Institutions

Publication Details

Journal
Cochlear Implants International
Published
2026-07-27
DOI
https://doi.org/10.1080/14670100.2026.2686528
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cochlear implant electrode insertion complication in a group of over 300 paediatric recipients

Zdenka Aksenovová, Zuzana Balatková, Michal Jurovčík, J Skrĭvan et al.
Cochlear Implants International
Hearing Loss and Rehabilitation
article

Cochlear implant electrode insertion complication in a group of over 300 paediatric recipients

Zdenka Aksenovová, Zuzana Balatková, Michal Jurovčík, J Skrĭvan, Zdeněk Čada, Z. Libáková, V. Svobodová, K. Smolková
article en

Abstract

Objective: Electrode tip fold-over (TFO) represents a complication of cochlear implantation. TFO may lead to insertion trauma and malfunction of the cochlear implant (CI), often requiring re-implantation. It is mostly associated with pre-shaped CI electrodes.Methods: Our aim was to provide a systematic literature review to examine the current rate of electrode TFO with different commercially available electrode types and compare it with our clinical experience. We performed a retrospective analysis of 370 paediatric CI patients up to 19 years of age, who underwent surgery at our department between 2014 and 2024. We studied laterality, diagnostic findings that revealed a TFO, and subsequent therapeutic solutions.Results: Intraoperative plain film X-ray and neural response telemetry (NRT) were performed during surgeries. In total, 585 ears were operated (unilateral, metachronic, and synchronic bilateral implantation). Straight electrodes were used in 26.3% and pre-shaped electrodes in 73.7% of surgeries. TFO was diagnosed in 17 cases (2.8%), including 11 male (65%) and 6 female (35%) patients. Most TFO complications were caused by pre-shaped electrodes (15 out of 17). There were 14 TFOs on the right side and 3 on the left. TFO was diagnosed mostly by X-ray. NRT was not proven to be a reliable method to detect a TFO.Conclusions: According to our review of 7550 CI surgeries, TFOs were identified in 222 ears with pre-shaped electrodes (4.2% incidence) and 13 ears with straight electrodes (0.57% incidence). In our cohort, the total occurrence of TFO was 2.8%, predominantly caused by pre-shaped electrode arrays compared to straight arrays.

Cochlear Implants International
Charles University (CZ), University Hospital in Motol (CZ)
Openalex Percentile: Top 7%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.