Hard-Particle Surface Stabilization and Data-Driven Wear Prediction in TiB2-Reinforced Heat-Polymerized PMMA Denture Base Composites

Poly(methyl methacrylate) (PMMA) remains a clinically important denture base polymer because of its favorable processability, aesthetics, repairability and long-term prosthodontic use; however, its limited surface hardness and susceptibility to sliding-induced degradation constrain surface durability. This study establishes the structure–chemistry–microstructure–tribology relationships and composition-window predictive behavior of heat-polymerized PMMA reinforced with titanium diboride (TiB2). PMMA/TiB2 composites containing 1, 3 and 5 wt.% TiB2 were prepared and compared with unreinforced PMMA. X-ray diffraction confirmed preservation of the broad amorphous/semi-amorphous PMMA response, while TiB2-related crystalline features became increasingly detectable with reinforcement content. ATR-FTIR showed retention of the characteristic C–H, ester C=O and C–O/C–O–C vibrations. SEM/EDS demonstrated progressively greater particle-related surface contrast and local Ti/B-associated elemental signatures. Vickers microhardness increased from 20.0 ± 0.7 to 35.0 ± 1.39 HV0.03, corresponding to a 75.0% improvement at 5 wt.% TiB2. After 1000 m of dry sliding, total mass loss decreased from 32.4 ± 0.5 to 14.9 ± 0.4 mg (54.0% reduction), overall coefficient of friction decreased from 0.58 to 0.35, and representative wear-track width decreased from 481.4 to 101.8 µm. A parsimonious distance–composition interaction model retained strong grouped leave-one-composition-out performance for cumulative wear (R2 = 0.9622; RMSE = 1.53 mg), while a linear composition model provided the most robust hardness prediction (R2 = 0.9317; RMSE = 1.50 HV0.03). More complex nonlinear models did not improve prediction for held-out compositions. Within the investigated 0–5 wt.% window, 5 wt.% TiB2 provided the most effective combination of matrix preservation, surface hardening, wear suppression and frictional stabilization.

Authors

Institutions

Publication Details

Journal
Crystals
Published
2026-07-28
DOI
https://doi.org/10.3390/cryst16080494
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hard-Particle Surface Stabilization and Data-Driven Wear Prediction in TiB2-Reinforced Heat-Polymerized PMMA Denture Base Composites

Ukbe Üsame UÇAR, Cevher Kürşat Macit, Ali Sincar, Ethem Furkan Hıdır et al.
Crystals
Orthopaedic implants and arthroplasty
article

Hard-Particle Surface Stabilization and Data-Driven Wear Prediction in TiB2-Reinforced Heat-Polymerized PMMA Denture Base Composites

Ukbe Üsame UÇAR, Cevher Kürşat Macit, Ali Sincar, Ethem Furkan Hıdır, Samet Tekin
article en

Abstract

Poly(methyl methacrylate) (PMMA) remains a clinically important denture base polymer because of its favorable processability, aesthetics, repairability and long-term prosthodontic use; however, its limited surface hardness and susceptibility to sliding-induced degradation constrain surface durability. This study establishes the structure–chemistry–microstructure–tribology relationships and composition-window predictive behavior of heat-polymerized PMMA reinforced with titanium diboride (TiB2). PMMA/TiB2 composites containing 1, 3 and 5 wt.% TiB2 were prepared and compared with unreinforced PMMA. X-ray diffraction confirmed preservation of the broad amorphous/semi-amorphous PMMA response, while TiB2-related crystalline features became increasingly detectable with reinforcement content. ATR-FTIR showed retention of the characteristic C–H, ester C=O and C–O/C–O–C vibrations. SEM/EDS demonstrated progressively greater particle-related surface contrast and local Ti/B-associated elemental signatures. Vickers microhardness increased from 20.0 ± 0.7 to 35.0 ± 1.39 HV0.03, corresponding to a 75.0% improvement at 5 wt.% TiB2. After 1000 m of dry sliding, total mass loss decreased from 32.4 ± 0.5 to 14.9 ± 0.4 mg (54.0% reduction), overall coefficient of friction decreased from 0.58 to 0.35, and representative wear-track width decreased from 481.4 to 101.8 µm. A parsimonious distance–composition interaction model retained strong grouped leave-one-composition-out performance for cumulative wear (R2 = 0.9622; RMSE = 1.53 mg), while a linear composition model provided the most robust hardness prediction (R2 = 0.9317; RMSE = 1.50 HV0.03). More complex nonlinear models did not improve prediction for held-out compositions. Within the investigated 0–5 wt.% window, 5 wt.% TiB2 provided the most effective combination of matrix preservation, surface hardening, wear suppression and frictional stabilization.

CrystalsVol. 16(8)
University of Turku (FI), PLA Air Force Aviation University (CN)
Sustainable cities and communities
Openalex Percentile: Top 7%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.