Percutaneous closure of an iatrogenic left atrial-aortic perforation complicated by cardiac tamponade and coronary vasospasm during transseptal puncture: a case report

Iatrogenic atrial-aortic perforation during transseptal puncture is a rare but potentially life-threatening complication. Percutaneous closure using dedicated occluder devices has emerged as a less invasive alternative to surgical repair in selected patients. A 68-year-old woman with hypertension and long-standing persistent atrial fibrillation (≥ 12 years) underwent catheter ablation. Pre-procedural imaging showed a markedly elevated left atrial (LA) volume (171 mL) with predominantly lateral enlargement. During a second transseptal puncture attempt, the sheath-dilator system inadvertently advanced through the LA wall and perforated the sinotubular junction of the aorta, confirmed by aortography. Although the sheath initially tamponaded the perforation, subsequent migration led to rapid hemopericardium requiring cardiopulmonary resuscitation (CPR) and emergent pericardiocentesis. With the access tract preserved, a 12/10 mm Amplatzer Duct Occluder was delivered percutaneously, achieving successful closure. Following device deployment, sudden cardiac arrest occurred due to diffuse coronary vasospasm, which resolved rapidly with intracoronary nitroglycerin. The patient was discharged in stable condition on an oral anticoagulant, a calcium channel blocker, and long-term nitrates. This case describes the successful percutaneous management of an iatrogenic LA-to-ascending aorta perforation during transseptal catheterization, complicated by cardiac tamponade and coronary vasospasm. This case suggests that careful attention is warranted not only during the septal puncture itself, but also during subsequent sheath advancement, even after successful entry into the LA has been confirmed.

Authors

Institutions

Publication Details

Journal
BMC Cardiovascular Disorders
Published
2026-07-28
DOI
https://doi.org/10.1186/s12872-026-06334-2
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Percutaneous closure of an iatrogenic left atrial-aortic perforation complicated by cardiac tamponade and coronary vasospasm during transseptal puncture: a case report

Jinho Lee, Young‐Shin Lee
BMC Cardiovascular Disorders
Atrial Fibrillation Management and Outcomes
article

Percutaneous closure of an iatrogenic left atrial-aortic perforation complicated by cardiac tamponade and coronary vasospasm during transseptal puncture: a case report

Jinho Lee, Young‐Shin Lee
article en

Abstract

Iatrogenic atrial-aortic perforation during transseptal puncture is a rare but potentially life-threatening complication. Percutaneous closure using dedicated occluder devices has emerged as a less invasive alternative to surgical repair in selected patients. A 68-year-old woman with hypertension and long-standing persistent atrial fibrillation (≥ 12 years) underwent catheter ablation. Pre-procedural imaging showed a markedly elevated left atrial (LA) volume (171 mL) with predominantly lateral enlargement. During a second transseptal puncture attempt, the sheath-dilator system inadvertently advanced through the LA wall and perforated the sinotubular junction of the aorta, confirmed by aortography. Although the sheath initially tamponaded the perforation, subsequent migration led to rapid hemopericardium requiring cardiopulmonary resuscitation (CPR) and emergent pericardiocentesis. With the access tract preserved, a 12/10 mm Amplatzer Duct Occluder was delivered percutaneously, achieving successful closure. Following device deployment, sudden cardiac arrest occurred due to diffuse coronary vasospasm, which resolved rapidly with intracoronary nitroglycerin. The patient was discharged in stable condition on an oral anticoagulant, a calcium channel blocker, and long-term nitrates. This case describes the successful percutaneous management of an iatrogenic LA-to-ascending aorta perforation during transseptal catheterization, complicated by cardiac tamponade and coronary vasospasm. This case suggests that careful attention is warranted not only during the septal puncture itself, but also during subsequent sheath advancement, even after successful entry into the LA has been confirmed.

BMC Cardiovascular Disorders
Kyung Hee University (KR), Kyung Hee University Medical Center (KR)
Openalex Percentile: Top 9%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.