Development and Validation of Isocratic RP‐UHPLC Method for Assay of Fenofibrate Tablet

ABSTRACT A method developed and validated for the assay of fenofibrate in tablet dosage form by isocratic RP‐UHPLC–UV technique has been rapid and precise. The material was chromatographed on Shim‐pack Velox C18 column (50 × 2.1 mm, 1.8 μm) at 40°C with isocratic mobile phase: acidified water/acetonitrile (60:40, v/v) at 0.4 mL/min and at a detection wavelength of 286 nm. The total run time was 6.0 min and fenofibrate eluted at ~2.4 min. The method was linear over 10–90 μg/mL (r 2 = 0.9995) with LOD/LOQ of 0.239/0.673 μg/mL. The precision and accuracy (RSD less than 2% and 96%–100% recovery) comply with ICH Q2(R1) requirements both intra‐day and inter‐day. The present UHPLC method significantly shortens the analysis time and solvent consumption compared with the reported HPLC methods (typical run time > 8–20 min) without compromising of the sensitivity, which allows to use the present method for routine quality control of fenofibrate tablets.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-07-28
DOI
https://doi.org/10.1002/bmc.70577
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of Isocratic RP‐UHPLC Method for Assay of Fenofibrate Tablet

Saurav Kumar, S.K. Sharma, Parijat Pandey, Dhirender Kaushik et al.
Biomedical Chromatography
Analytical Methods in Pharmaceuticals
article

Development and Validation of Isocratic RP‐UHPLC Method for Assay of Fenofibrate Tablet

Saurav Kumar, S.K. Sharma, Parijat Pandey, Dhirender Kaushik, Prabodh. C. Sharma, Jyoti Yadav
article en

Abstract

ABSTRACT A method developed and validated for the assay of fenofibrate in tablet dosage form by isocratic RP‐UHPLC–UV technique has been rapid and precise. The material was chromatographed on Shim‐pack Velox C18 column (50 × 2.1 mm, 1.8 μm) at 40°C with isocratic mobile phase: acidified water/acetonitrile (60:40, v/v) at 0.4 mL/min and at a detection wavelength of 286 nm. The total run time was 6.0 min and fenofibrate eluted at ~2.4 min. The method was linear over 10–90 μg/mL (r 2 = 0.9995) with LOD/LOQ of 0.239/0.673 μg/mL. The precision and accuracy (RSD less than 2% and 96%–100% recovery) comply with ICH Q2(R1) requirements both intra‐day and inter‐day. The present UHPLC method significantly shortens the analysis time and solvent consumption compared with the reported HPLC methods (typical run time > 8–20 min) without compromising of the sensitivity, which allows to use the present method for routine quality control of fenofibrate tablets.

Biomedical ChromatographyVol. 40(9)
Shree Guru Gobind Singh Tricentenary University (IN), Delhi Pharmaceutical Science and Research University (IN), Vikram University (IN)
Clean water and sanitation
Openalex Percentile: Top 12%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.