Validation of a Machine Learning Approach to the Analysis of Multifocal Electroretinograms for Hydroxychloroquine Retinopathy

Purpose: Hydroxychloroquine (HCQ) retinopathy is detectable through multimodal ophthalmic screening, yet individual diagnostic tests each have inherent limitations. Machine learning may simplify monitoring, but few HCQ screening algorithms have undergone rigorous external validation. This study evaluated the clinical utility of the Multifocal Electroretinogram Classification Interface (MERCI) algorithm by assessing its ability to predict HCQ retinopathy compared with diagnoses derived from American Academy of Ophthalmology (AAO) guidelines. Methods: Patients referred for HCQ toxicity screening underwent perimetry, spectral-domain optical coherence tomography, fundus autofluorescence photography, and multifocal electroretinogram (mfERG) testing. Performance was assessed in a temporal dataset (participants overlapping with the development dataset) and a novel dataset (newly enrolled participants). Reference diagnoses were assigned using AAO guideline-based decision trees informed by ancillary tests results. MERCI generated corresponding mfERG-based predictions, which were compared with reference diagnoses to compute performance metrics for each dataset. Results: Using the decision trees, the temporal (n = 145) and novel (n = 300) datasets showed retinopathy prevalences of 12.4% and 9.7%, respectively. MERCI yielded 63/145 (43.4%) and 115/300 (38.3%) false-positive cases, respectively. MERCI achieved strong sensitivity (1.000 temporal; 0.931 novel) and negative predictive value (NPV) (1.000 temporal; 0.987 novel), with comparable area under the curve between datasets (0.759 temporal; 0.805 novel). Conclusions: MERCI retained high sensitivity and NPV when validated against temporally distinct cohorts using a clinical definition of HCQ toxicity. This suggests MERCI's potential as a screening tool for HCQ retinopathy. Translational Relevance: The mfERG-based machine learning models may improve screening efficiency and clinical decision-making for HCQ users.

Authors

Institutions

Publication Details

Journal
Translational Vision Science & Technology
Published
2026-07-28
DOI
https://doi.org/10.1167/tvst.15.7.29
Primary Topic
Drug-Induced Ocular Toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a Machine Learning Approach to the Analysis of Multifocal Electroretinograms for Hydroxychloroquine Retinopathy

Gareth Mercer, Brian G. Ballios, Godfrey Wong, Tom Wright
Translational Vision Science & Technology
Drug-Induced Ocular Toxicity
article

Validation of a Machine Learning Approach to the Analysis of Multifocal Electroretinograms for Hydroxychloroquine Retinopathy

Gareth Mercer, Brian G. Ballios, Godfrey Wong, Tom Wright
article en

Abstract

Purpose: Hydroxychloroquine (HCQ) retinopathy is detectable through multimodal ophthalmic screening, yet individual diagnostic tests each have inherent limitations. Machine learning may simplify monitoring, but few HCQ screening algorithms have undergone rigorous external validation. This study evaluated the clinical utility of the Multifocal Electroretinogram Classification Interface (MERCI) algorithm by assessing its ability to predict HCQ retinopathy compared with diagnoses derived from American Academy of Ophthalmology (AAO) guidelines. Methods: Patients referred for HCQ toxicity screening underwent perimetry, spectral-domain optical coherence tomography, fundus autofluorescence photography, and multifocal electroretinogram (mfERG) testing. Performance was assessed in a temporal dataset (participants overlapping with the development dataset) and a novel dataset (newly enrolled participants). Reference diagnoses were assigned using AAO guideline-based decision trees informed by ancillary tests results. MERCI generated corresponding mfERG-based predictions, which were compared with reference diagnoses to compute performance metrics for each dataset. Results: Using the decision trees, the temporal (n = 145) and novel (n = 300) datasets showed retinopathy prevalences of 12.4% and 9.7%, respectively. MERCI yielded 63/145 (43.4%) and 115/300 (38.3%) false-positive cases, respectively. MERCI achieved strong sensitivity (1.000 temporal; 0.931 novel) and negative predictive value (NPV) (1.000 temporal; 0.987 novel), with comparable area under the curve between datasets (0.759 temporal; 0.805 novel). Conclusions: MERCI retained high sensitivity and NPV when validated against temporally distinct cohorts using a clinical definition of HCQ toxicity. This suggests MERCI's potential as a screening tool for HCQ retinopathy. Translational Relevance: The mfERG-based machine learning models may improve screening efficiency and clinical decision-making for HCQ users.

Translational Vision Science & TechnologyVol. 15(7)
St. Michael's Hospital (CA), University of Toronto (CA), Toronto Rehabilitation Institute (CA), Kensington Health (CA)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Drug-Induced Ocular Toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.