A Critical Comparative Review of Analytical Techniques for Cloxacillin and Oxacillin Across Diverse Matrices

Cloxacillin (CLX) and oxacillin (OXA), two isoxazolyl β-lactam antibiotics widely used against penicillinase-producing Staphylococcus aureus, have attracted increasing attention due to their environmental persistence, residue occurrence, and analytical complexity across diverse matrices. This review provides a critical and integrated comparison of analytical techniques for the determination of CLX and OXA in pharmaceutical, biological, food, and environmental samples, addressing key challenges, including β-lactam instability, low intrinsic detectability, strong protein binding, and matrix interferences. Chromatographic methods, particularly HPLC and LC-MS/MS, remain the most reliable approaches, offering high selectivity and stability-indicating capability, with LC-MS/MS achieving superior sensitivity at ng/mL levels suitable for trace analysis, albeit at higher cost and with greater operational demands. Electrochemical techniques, especially nanomaterial- and molecularly imprinted-based sensors, demonstrate promising sensitivity and rapid response, though limitations in reproducibility and standardization persist. In contrast, spectroscopic methods are economical and simple but restricted by low sensitivity and poor selectivity in complex matrices. Overall, no single technique is universally optimal, and analytical performance is strongly matrix-dependent. Future perspectives should prioritize the development of hybrid, standardized, and green analytical platforms that balance sensitivity, robustness, and cost-effectiveness, alongside harmonized validation strategies to enable reliable and sustainable monitoring of CLX and OXA in real-world applications.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-07-28
DOI
https://doi.org/10.1002/bmc.70571
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Critical Comparative Review of Analytical Techniques for Cloxacillin and Oxacillin Across Diverse Matrices

Hemn A.H. Barzani, Rebaz Anwar Omer, Kovan Dilawer Issa, Seerwan Hamadameen Sulaiman et al.
Biomedical Chromatography
Antibiotics Pharmacokinetics and Efficacy
article

A Critical Comparative Review of Analytical Techniques for Cloxacillin and Oxacillin Across Diverse Matrices

Hemn A.H. Barzani, Rebaz Anwar Omer, Kovan Dilawer Issa, Seerwan Hamadameen Sulaiman, Hunar Yasin Muhammad, Ali Sedeeq Noaman, Khalamala Ibrahim Salih Barzani
article en

Abstract

Cloxacillin (CLX) and oxacillin (OXA), two isoxazolyl β-lactam antibiotics widely used against penicillinase-producing Staphylococcus aureus, have attracted increasing attention due to their environmental persistence, residue occurrence, and analytical complexity across diverse matrices. This review provides a critical and integrated comparison of analytical techniques for the determination of CLX and OXA in pharmaceutical, biological, food, and environmental samples, addressing key challenges, including β-lactam instability, low intrinsic detectability, strong protein binding, and matrix interferences. Chromatographic methods, particularly HPLC and LC-MS/MS, remain the most reliable approaches, offering high selectivity and stability-indicating capability, with LC-MS/MS achieving superior sensitivity at ng/mL levels suitable for trace analysis, albeit at higher cost and with greater operational demands. Electrochemical techniques, especially nanomaterial- and molecularly imprinted-based sensors, demonstrate promising sensitivity and rapid response, though limitations in reproducibility and standardization persist. In contrast, spectroscopic methods are economical and simple but restricted by low sensitivity and poor selectivity in complex matrices. Overall, no single technique is universally optimal, and analytical performance is strongly matrix-dependent. Future perspectives should prioritize the development of hybrid, standardized, and green analytical platforms that balance sensitivity, robustness, and cost-effectiveness, alongside harmonized validation strategies to enable reliable and sustainable monitoring of CLX and OXA in real-world applications.

Biomedical ChromatographyVol. 40(9)
Sulaimani Polytechnic University (IQ), Lebanese French University (IQ), Salahaddin University-Erbil (IQ), Koya University (IQ), University of Duhok (IQ), Tishk International University (IQ)
Openalex Percentile: Top 10%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.