Different Center of Rotation Trajectories after Cervical Hybrid Surgery: A Minimum 7-Year Retrospective Comparison of Bryan and Mobi-C Prostheses

Study Design Retrospective Study. Objectives To compare long-term adjacent-segment kinematic changes and radiographic adjacent segment degeneration (rASD) after two-level cervical hybrid surgery using Bryan or Mobi-C prostheses. Methods We retrospectively reviewed 78 patients who underwent contiguous two-level anterior cervical hybrid surgery between 2010 and 2018, including 38 treated with Bryan and 40 with Mobi-C prostheses. All patients had more than 7 years of follow-up. Flexion-extension center of rotation (FE-COR) trajectories at the superior adjacent segment were measured on dynamic radiographs. Long-term rASD was evaluated using the Walraevens score. Results Clinical outcomes improved significantly in both groups (P < 0.001), with no significant between-group differences. Segmental range of motion remained stable and comparable between groups (P > 0.05). However, FE-COR trajectories differed. At 1 year, the Mobi-C group showed anterior-inferior FE-COR displacement, with FE-COR_Y decreasing to 44.92% ± 12.55%, whereas the Bryan group maintained a relatively stable FE-COR_Y of 59.01% ± 10.66% (P < 0.001). At final follow-up, rASD occurred in 12.5% of Mobi-C patients and 23.7% of Bryan patients, although this difference was not statistically significant (P = 0.198). Conclusion Conventional ROM measurements alone cannot fully capture segmental biomechanics. Early anterior-inferior FE-COR displacement in the Mobi-C group was observed and was associated with a numerically lower, but statistically non-significant, rASD rate. These findings suggest that FE-COR may be a sensitive radiographic parameter for describing postoperative micro-kinematic patterns, but its causal relationship with long-term adjacent segment degeneration requires further biomechanical and MRI-based validation.

Authors

Institutions

Publication Details

Journal
Global Spine Journal
Published
2026-07-28
DOI
https://doi.org/10.1177/21925682261474153
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Different Center of Rotation Trajectories after Cervical Hybrid Surgery: A Minimum 7-Year Retrospective Comparison of Bryan and Mobi-C Prostheses

Guozheng Jiang, Yang Wang, Ziye Qiu, Xing Yu et al.
Global Spine Journal
Cervical and Thoracic Myelopathy
article

Different Center of Rotation Trajectories after Cervical Hybrid Surgery: A Minimum 7-Year Retrospective Comparison of Bryan and Mobi-C Prostheses

Guozheng Jiang, Yang Wang, Ziye Qiu, Xing Yu, Jiaqi Zhang, Yukun Ma, Daiyuan Zhang, Yang Xiong
article en

Abstract

Study Design Retrospective Study. Objectives To compare long-term adjacent-segment kinematic changes and radiographic adjacent segment degeneration (rASD) after two-level cervical hybrid surgery using Bryan or Mobi-C prostheses. Methods We retrospectively reviewed 78 patients who underwent contiguous two-level anterior cervical hybrid surgery between 2010 and 2018, including 38 treated with Bryan and 40 with Mobi-C prostheses. All patients had more than 7 years of follow-up. Flexion-extension center of rotation (FE-COR) trajectories at the superior adjacent segment were measured on dynamic radiographs. Long-term rASD was evaluated using the Walraevens score. Results Clinical outcomes improved significantly in both groups (P < 0.001), with no significant between-group differences. Segmental range of motion remained stable and comparable between groups (P > 0.05). However, FE-COR trajectories differed. At 1 year, the Mobi-C group showed anterior-inferior FE-COR displacement, with FE-COR_Y decreasing to 44.92% ± 12.55%, whereas the Bryan group maintained a relatively stable FE-COR_Y of 59.01% ± 10.66% (P < 0.001). At final follow-up, rASD occurred in 12.5% of Mobi-C patients and 23.7% of Bryan patients, although this difference was not statistically significant (P = 0.198). Conclusion Conventional ROM measurements alone cannot fully capture segmental biomechanics. Early anterior-inferior FE-COR displacement in the Mobi-C group was observed and was associated with a numerically lower, but statistically non-significant, rASD rate. These findings suggest that FE-COR may be a sensitive radiographic parameter for describing postoperative micro-kinematic patterns, but its causal relationship with long-term adjacent segment degeneration requires further biomechanical and MRI-based validation.

Global Spine Journal
Capital University (US), Beijing University of Chinese Medicine (CN), Capital Medical University (CN), Dongzhimen Hospital Affiliated to Beijing University of Chinese Medicine (CN), Yanbian University Hospital (CN), Beijing Hospital of Traditional Chinese Medicine (CN), Tsinghua University (CN)
Openalex Percentile: Top 7%
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.