The diagnostic potential of combined quantitative polymerase chain reaction and next-generation sequencing using the same primers for periprosthetic joint infection

ABSTRACT Next-generation sequencing (NGS) enables the detection of specific pathogens unidentifiable by conventional cultures, but its application in orthopedics remains inconsistent due to background contamination and irreproducible findings. This study evaluated the diagnostic performance of a novel workflow combining broad-range 16S rRNA gene quantitative PCR (qPCR) screening with downstream NGS, focusing on bacterial biomass thresholds. The qPCR assay demonstrated excellent intrarater reliability, with an intraclass correlation coefficient (ICC) of 0.961 (95% confidence interval, 0.881 to 0.997). Based on serially diluted positive controls, a quantitative threshold of 10⁵ CFU/mL was established as the minimum concentration required for the consistent detection of fastidious taxa, such as Escherichia coli . When evaluated against conventional cultures using 95 sonicate fluid and 276 pre/intraoperative tissue samples, the qPCR assay achieved a sensitivity of 80% and a specificity of 72%. Subsequent NGS sequencing of 26 clinical samples and 9 controls showed concordance in 4 of 6 culture-positive infected cases with NGS taxonomy, whereas the remaining discrepancies were likely attributable to culture-based phenotypic misidentification. Notably, among the qPCR-positive cases, three were culture-negative, including two hip prosthesis loosening cases exhibiting polymicrobial profiles, and one post-traumatic osteoarthritis case harboring low-level Staphylococcus . Crucially, this post-traumatic patient developed delayed periprosthetic joint infection (PJI) 2 years post-surgery, with cultures identifying Staphylococcus previously detected by the initial NGS analysis. Integrating qPCR screening with targeted NGS effectively refines pathogen identification, filters environmental artifacts, and overcomes the diagnostic limitations of culture-negative infections in orthopedic practice. IMPORTANCE Next-generation sequencing (NGS) enables the detection of specific pathogens in clinical samples that are not identifiable by conventional methods. However, NGS applications in orthopedics have not been quantitatively evaluated, and findings have been inconsistent owing to contaminants and the presence of non-credible causative organisms. These factors primarily stem from the failure to evaluate low-biomass samples and the absence of proper controls, such as negative controls or mock community DNA samples. This study demonstrates that interpreting results from low-biomass samples requires careful consideration because NGS relies on relative bacterial abundances; distinguishing likely pathogens from contaminants is particularly challenging when bacterial loads are low. We demonstrated that combining NGS with quantitative PCR (qPCR) and applying a Cq cutoff can reduce false positives.

Authors

Institutions

Publication Details

Journal
Microbiology Spectrum
Published
2026-07-28
DOI
https://doi.org/10.1128/spectrum.04128-25
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The diagnostic potential of combined quantitative polymerase chain reaction and next-generation sequencing using the same primers for periprosthetic joint infection

Narumi Ueda, Jun Inoue, Kazuyuki Okuda, Hirokazu Iida
Microbiology Spectrum
Orthopedic Infections and Treatments
article

The diagnostic potential of combined quantitative polymerase chain reaction and next-generation sequencing using the same primers for periprosthetic joint infection

Narumi Ueda, Jun Inoue, Kazuyuki Okuda, Hirokazu Iida
article en

Abstract

ABSTRACT Next-generation sequencing (NGS) enables the detection of specific pathogens unidentifiable by conventional cultures, but its application in orthopedics remains inconsistent due to background contamination and irreproducible findings. This study evaluated the diagnostic performance of a novel workflow combining broad-range 16S rRNA gene quantitative PCR (qPCR) screening with downstream NGS, focusing on bacterial biomass thresholds. The qPCR assay demonstrated excellent intrarater reliability, with an intraclass correlation coefficient (ICC) of 0.961 (95% confidence interval, 0.881 to 0.997). Based on serially diluted positive controls, a quantitative threshold of 10⁵ CFU/mL was established as the minimum concentration required for the consistent detection of fastidious taxa, such as Escherichia coli . When evaluated against conventional cultures using 95 sonicate fluid and 276 pre/intraoperative tissue samples, the qPCR assay achieved a sensitivity of 80% and a specificity of 72%. Subsequent NGS sequencing of 26 clinical samples and 9 controls showed concordance in 4 of 6 culture-positive infected cases with NGS taxonomy, whereas the remaining discrepancies were likely attributable to culture-based phenotypic misidentification. Notably, among the qPCR-positive cases, three were culture-negative, including two hip prosthesis loosening cases exhibiting polymicrobial profiles, and one post-traumatic osteoarthritis case harboring low-level Staphylococcus . Crucially, this post-traumatic patient developed delayed periprosthetic joint infection (PJI) 2 years post-surgery, with cultures identifying Staphylococcus previously detected by the initial NGS analysis. Integrating qPCR screening with targeted NGS effectively refines pathogen identification, filters environmental artifacts, and overcomes the diagnostic limitations of culture-negative infections in orthopedic practice. IMPORTANCE Next-generation sequencing (NGS) enables the detection of specific pathogens in clinical samples that are not identifiable by conventional methods. However, NGS applications in orthopedics have not been quantitatively evaluated, and findings have been inconsistent owing to contaminants and the presence of non-credible causative organisms. These factors primarily stem from the failure to evaluate low-biomass samples and the absence of proper controls, such as negative controls or mock community DNA samples. This study demonstrates that interpreting results from low-biomass samples requires careful consideration because NGS relies on relative bacterial abundances; distinguishing likely pathogens from contaminants is particularly challenging when bacterial loads are low. We demonstrated that combining NGS with quantitative PCR (qPCR) and applying a Cq cutoff can reduce false positives.

Microbiology Spectrum
Kansai Medical University (JP), Japanese Red Cross Society Wakayama Medical Center (JP), Kobe University (JP)
Life in Land
Openalex Percentile: Top 7%
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.