Dual-monomer molecularly imprinted polymer sensor for paracetamol voltammetric determination

Paracetamol is an emerging pharmaceutical contaminant widely detected in aquatic environments because of its large-scale consumption and persistence through conventional wastewater treatment processes. Even at trace levels, its continuous input into water bodies raises environmental concern and demands sensitive and selective analytical approaches for reliable monitoring. In this work, a screen-printed electrode (SPE) modified with a molecularly imprinted polymer (MIP) was developed for PAR quantification. The carbon-based SPEs were produced in the laboratory from a conductive ink composed of graphite powder, nanographite (surface-enhanced flake graphite), and alkyd resin. Functional monomers were selected based on molecular modeling using quantum mechanics calculations. The MIP film was prepared by direct electropolymerization on the SPE, using chronoamperometry from a solution containing caffeic acid and L-methionine as monomers, and PAR as the template molecule. A non-imprinted polymer (NIP) film was obtained following the same methodology, but in the absence of PAR. The sensors were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Under optimized conditions, calibration curves for PAR were obtained using unmodified SPE, NIP sensor, and MIP sensor, with detection limits of 4.4 × 10 – 6 , 2.7 × 10 – 6 , and 5.0 × 10 – 8 mol L – 1 , respectively. The MIP sensor showed adequate selectivity, and good reproducibility (RSD = 6.3%), stability (85 days) and reusability (up to 7 measurements, with recalibration) or use for a single analysis (disposable). The MIP sensor was successfully applied in the analysis of PAR in aqueous matrices, with relative error below 10%.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2026-07-27
DOI
https://doi.org/10.1007/s42452-026-09194-9
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-monomer molecularly imprinted polymer sensor for paracetamol voltammetric determination

Thaynara Dannehl Hoppe, José Wilmo da Cruz Júnior, Thiago Henrique Doring, Daniela Brondani et al.
Discover Applied Sciences
Electrochemical sensors and biosensors
article

Dual-monomer molecularly imprinted polymer sensor for paracetamol voltammetric determination

Thaynara Dannehl Hoppe, José Wilmo da Cruz Júnior, Thiago Henrique Doring, Daniela Brondani, Ismael C. Bellettini
article en

Abstract

Paracetamol is an emerging pharmaceutical contaminant widely detected in aquatic environments because of its large-scale consumption and persistence through conventional wastewater treatment processes. Even at trace levels, its continuous input into water bodies raises environmental concern and demands sensitive and selective analytical approaches for reliable monitoring. In this work, a screen-printed electrode (SPE) modified with a molecularly imprinted polymer (MIP) was developed for PAR quantification. The carbon-based SPEs were produced in the laboratory from a conductive ink composed of graphite powder, nanographite (surface-enhanced flake graphite), and alkyd resin. Functional monomers were selected based on molecular modeling using quantum mechanics calculations. The MIP film was prepared by direct electropolymerization on the SPE, using chronoamperometry from a solution containing caffeic acid and L-methionine as monomers, and PAR as the template molecule. A non-imprinted polymer (NIP) film was obtained following the same methodology, but in the absence of PAR. The sensors were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Under optimized conditions, calibration curves for PAR were obtained using unmodified SPE, NIP sensor, and MIP sensor, with detection limits of 4.4 × 10 – 6 , 2.7 × 10 – 6 , and 5.0 × 10 – 8 mol L – 1 , respectively. The MIP sensor showed adequate selectivity, and good reproducibility (RSD = 6.3%), stability (85 days) and reusability (up to 7 measurements, with recalibration) or use for a single analysis (disposable). The MIP sensor was successfully applied in the analysis of PAR in aqueous matrices, with relative error below 10%.

Discover Applied Sciences
Universidade Federal de Santa Catarina (BR), Institute of Physics (PL), Universidade Regional de Blumenau (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e Inovação do Estado de Santa Catarina
Affordable and clean energy
Openalex Percentile: Top 16%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.