Image‐Derived Volumetry During Forced Expiration Using a <scp>3D</scp> Fermat Looped, Orthogonally Encoded Trajectory

PURPOSE: To enable MRI-based nongated 3D depiction of forced expiration with both high spatio-temporal resolution and fidelity of lung dynamics. METHODS: An undersampled 3D Fermat looped, orthogonally encoded trajectory (FLORET) was optimized for nonsegmented dynamic acquisitions during forced expiration and a corresponding model-based reconstruction pipeline promoting spatial and temporal total variation was implemented. The approach was first optimized and validated using a lung phantom, specifically constructed for this study and was then translated to in vivo measurements. This allowed high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm. RESULTS: Volumes derived by segmenting the MR images of the phantom demonstrated excellent agreement with the air exchange measured directly at the phantom within the bore, therefore confirming the validity of the approach. In both phantom and in vivo experiments, the dynamic deflation process could be successfully depicted, confirming the potential for assessing forced expiration with 3D UTE FLORET MRI. From the segmented volumes in vivo, quantitative parameters were derived, including the duration of the dynamic phase (2.8 ± 0.2 s), the time to 90% deflation (1.8 ± 0.2 s), and the volume change within the first second (2.8 ± 0.2 L). CONCLUSION: The phantom and in vivo studies demonstrate, that the 3D FLORET trajectory can be utilized to study lung deflation during forced expiration with high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm using a TV-regularized primal-dual SENSE reconstruction. Acquisitions were performed for discrete distinct time frames, that is, no segmented k-space filling across several respiratory cycles was used.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-07-27
DOI
https://doi.org/10.1002/mrm.70545
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image‐Derived Volumetry During Forced Expiration Using a 3D Fermat Looped, Orthogonally Encoded Trajectory

Tobias Wech, Matthias Anders, Corona Metz, Simon Veldhoen et al.
Magnetic Resonance in Medicine
Atomic and Subatomic Physics Research
article

Image‐Derived Volumetry During Forced Expiration Using a 3D Fermat Looped, Orthogonally Encoded Trajectory

Tobias Wech, Matthias Anders, Corona Metz, Simon Veldhoen, Herbert Köstler, Sebastian Scheidel, Viktor Hartung
article en

Abstract

PURPOSE: To enable MRI-based nongated 3D depiction of forced expiration with both high spatio-temporal resolution and fidelity of lung dynamics. METHODS: An undersampled 3D Fermat looped, orthogonally encoded trajectory (FLORET) was optimized for nonsegmented dynamic acquisitions during forced expiration and a corresponding model-based reconstruction pipeline promoting spatial and temporal total variation was implemented. The approach was first optimized and validated using a lung phantom, specifically constructed for this study and was then translated to in vivo measurements. This allowed high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm. RESULTS: Volumes derived by segmenting the MR images of the phantom demonstrated excellent agreement with the air exchange measured directly at the phantom within the bore, therefore confirming the validity of the approach. In both phantom and in vivo experiments, the dynamic deflation process could be successfully depicted, confirming the potential for assessing forced expiration with 3D UTE FLORET MRI. From the segmented volumes in vivo, quantitative parameters were derived, including the duration of the dynamic phase (2.8 ± 0.2 s), the time to 90% deflation (1.8 ± 0.2 s), and the volume change within the first second (2.8 ± 0.2 L). CONCLUSION: The phantom and in vivo studies demonstrate, that the 3D FLORET trajectory can be utilized to study lung deflation during forced expiration with high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm using a TV-regularized primal-dual SENSE reconstruction. Acquisitions were performed for discrete distinct time frames, that is, no segmented k-space filling across several respiratory cycles was used.

Magnetic Resonance in Medicine
Humboldt-Universität zu Berlin (DE), Universitätsklinikum Würzburg (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 10%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.