Soft, Multi‐Wavelength Photoplethysmography Enables Reliable Neonatal Blood Pressure Monitoring Via Error Stratification

Continuous noninvasive blood pressure monitoring is important for neonatal hemodynamic management. However, cuffless photoplethysmography (PPG) is still difficult to use clinically because acquisition-related errors and their effects on blood pressure estimation are not well understood. Most studies report only overall error, which can hide error patterns under different signal-quality and motion conditions. Here, we developed a soft multi-wavelength wearable that combines reflective and transmissive optical paths to record complementary PPG signals. We also built NEO-BP, a prospective clinical dataset containing synchronized multi-wavelength PPG and invasive arterial blood pressure waveforms from 42 neonates. In a held-out segment-level test set without excluding samples based on signal quality (n = 9378), the green-red-infrared (G+R+IR) model achieved mean absolute errors of 9.67 mmHg for systolic blood pressure and 6.17 mmHg for diastolic blood pressure. Using this dataset, we established a retrospective descriptive subgroup error profile by stratifying estimation deviations across measurable acquisition and physiological conditions. Estimation errors increased under lower signal quality and stronger motion. These results identify error-prone acquisition states, support quality-aware interpretation of segment-level cuffless blood pressure estimates, and provide a basis for future models that estimate the error risk of individual readings.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2026-07-27
DOI
https://doi.org/10.1002/advs.76775
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Soft, Multi‐Wavelength Photoplethysmography Enables Reliable Neonatal Blood Pressure Monitoring Via Error Stratification

Ronghui Gao, Weiwei Guo, C J Chen, Yunfeng Lin et al.
Advanced Science
Non-Invasive Vital Sign Monitoring
article

Soft, Multi‐Wavelength Photoplethysmography Enables Reliable Neonatal Blood Pressure Monitoring Via Error Stratification

Ronghui Gao, Weiwei Guo, C J Chen, Yunfeng Lin, Lanlan Mi, Zisheng Dai, Jia‐Rong Chen, Biao Liu, G C Wang, Bin Liu, Wenqi Shi, Wenyi Luo, Min Wang
article en

Abstract

Continuous noninvasive blood pressure monitoring is important for neonatal hemodynamic management. However, cuffless photoplethysmography (PPG) is still difficult to use clinically because acquisition-related errors and their effects on blood pressure estimation are not well understood. Most studies report only overall error, which can hide error patterns under different signal-quality and motion conditions. Here, we developed a soft multi-wavelength wearable that combines reflective and transmissive optical paths to record complementary PPG signals. We also built NEO-BP, a prospective clinical dataset containing synchronized multi-wavelength PPG and invasive arterial blood pressure waveforms from 42 neonates. In a held-out segment-level test set without excluding samples based on signal quality (n = 9378), the green-red-infrared (G+R+IR) model achieved mean absolute errors of 9.67 mmHg for systolic blood pressure and 6.17 mmHg for diastolic blood pressure. Using this dataset, we established a retrospective descriptive subgroup error profile by stratifying estimation deviations across measurable acquisition and physiological conditions. Estimation errors increased under lower signal quality and stronger motion. These results identify error-prone acquisition states, support quality-aware interpretation of segment-level cuffless blood pressure estimates, and provide a basis for future models that estimate the error risk of individual readings.

Advanced Science
Shanghai Jiao Tong University (CN), Fujian Women and Children Hospital (CN), Shanghai Children's Medical Center (CN), Shenzhen Technology University (CN)
Shanghai Jiao Tong University, Fujian Provincial Department of Science and Technology
Quality Education
Openalex Percentile: Top 16%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.