BloodContourNet: A YOLO-Based Density-Aware Bézier Refinement Framework for Peripheral Blood Cell Detection

Background/Objectives: Accurate peripheral blood cell detection remains difficult in dense smear fields, where touching erythrocytes, small platelets, and staining variability reduce the reliability of box-based object detectors. This study aims to address these limitations by proposing BloodContourNet, a contour-informed and density-aware detection framework for red blood cell, white blood cell, and platelet localization. Method: BloodContourNet is built on YOLOv26-L and integrates three complementary modules. The Hematological Attention Module (HAM) refines high-level features using local convolution and shifted-window attention. The Density-Aware Reweighting Head (DARH) modulates the classification loss for locally sparse or difficult instances without image-level resampling. The Bézier Contour Refinement Head (BCRH) provides a weakly supervised geometric overlap cue for ambiguous dense-region post-processing. Results: Experiments on the TXL-PBC dataset, containing 1260 peripheral smear images and 18,143 annotated cells, benchmarked 25 YOLO variants and 10 Transformer-based or reference detectors under a unified split and evaluation protocol. Across five random seeds, BloodContourNet achieved 99.1% mean Average Precision (mAP) at 50% Intersection-over-Union (IoU) and 87.8% mAP@50:95, improving strict-IoU performance by 1.4 points over YOLOv26-L and 0.7 points over DINO-DETR. Both margins were statistically significant across the five seeds (paired two-sided t-tests, both p < 0.05), and the five-seed 95% confidence interval of the proposed model was [87.5, 88.0]. Conclusions: BloodContourNet primarily improved the strict-localization setting on TXL-PBC, where dense erythrocyte regions and small platelet instances remain challenging for box-based detectors. External patient- or slide-independent validation remains necessary before broader clinical claims can be made.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-27
DOI
https://doi.org/10.3390/diagnostics16152362
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BloodContourNet: A YOLO-Based Density-Aware Bézier Refinement Framework for Peripheral Blood Cell Detection

Merve Temizer Ersoy, Faruk Özger, İshak Paçal, Mustafa Yurdakul et al.
Diagnostics
Digital Imaging for Blood Diseases
article

BloodContourNet: A YOLO-Based Density-Aware Bézier Refinement Framework for Peripheral Blood Cell Detection

Merve Temizer Ersoy, Faruk Özger, İshak Paçal, Mustafa Yurdakul, Eda Dönmez
article en

Abstract

Background/Objectives: Accurate peripheral blood cell detection remains difficult in dense smear fields, where touching erythrocytes, small platelets, and staining variability reduce the reliability of box-based object detectors. This study aims to address these limitations by proposing BloodContourNet, a contour-informed and density-aware detection framework for red blood cell, white blood cell, and platelet localization. Method: BloodContourNet is built on YOLOv26-L and integrates three complementary modules. The Hematological Attention Module (HAM) refines high-level features using local convolution and shifted-window attention. The Density-Aware Reweighting Head (DARH) modulates the classification loss for locally sparse or difficult instances without image-level resampling. The Bézier Contour Refinement Head (BCRH) provides a weakly supervised geometric overlap cue for ambiguous dense-region post-processing. Results: Experiments on the TXL-PBC dataset, containing 1260 peripheral smear images and 18,143 annotated cells, benchmarked 25 YOLO variants and 10 Transformer-based or reference detectors under a unified split and evaluation protocol. Across five random seeds, BloodContourNet achieved 99.1% mean Average Precision (mAP) at 50% Intersection-over-Union (IoU) and 87.8% mAP@50:95, improving strict-IoU performance by 1.4 points over YOLOv26-L and 0.7 points over DINO-DETR. Both margins were statistically significant across the five seeds (paired two-sided t-tests, both p < 0.05), and the five-seed 95% confidence interval of the proposed model was [87.5, 88.0]. Conclusions: BloodContourNet primarily improved the strict-localization setting on TXL-PBC, where dense erythrocyte regions and small platelet instances remain challenging for box-based detectors. External patient- or slide-independent validation remains necessary before broader clinical claims can be made.

DiagnosticsVol. 16(15)
University of Turku (FI), Turku University of Applied Sciences (FI), Fenerbahçe University (TR), Istanbul University (TR), Nakhchivan State University (AZ)
Openalex Percentile: Top 9%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.