Cumulative Intervention Area and Reconfiguration Carbon Intensity: A Comparative LCA of Hybrid Dry Floor Systems in High-Churn Office Buildings

Office buildings accumulate embodied carbon not only during construction but repeatedly throughout operation, driven by tenant improvements (TI). In contexts where regulatory and supply-chain constraints limit full design-for-disassembly, this paper explores partial decoupling of a dry slab system within the high-churn zone of a Seoul office. Two area-normalised indicators are introduced—cumulative intervention area (Acum) and Reconfiguration Carbon Intensity (RCI)—defined on the structural slab/panel boundary to complement the mass-weighted Circularity Index (CI). The indicators are demonstrated on a 17-storey Seoul office over 60 years across three scenarios: a wet composite baseline (S1), full-dry CLT (S2), and a hybrid placing CLT within the high-churn zone (S3). S3 reduces RCI by approximately 45% relative to the wet baseline, capturing 71.7% of the full-decoupling benefit while converting only 11.5% of the floor area to CLT—a benefit-to-conversion ratio of 6.2×. Both shares are fixed by the floor-plate geometry, so this ratio is a consequence of the high-churn zone’s concentration rather than an independent empirical finding. A joint-uncertainty stress test confirms that S3 outcomes lie entirely below S1 across plausible parameter ranges. A placement test compares three configurations of the same floor that differ only in CLT placement location relative to the high-churn zone. Mass-weighted CI cannot distinguish these configurations, whereas RCI ranges from no reduction to the full hybrid benefit depending on placement—isolating the diagnostic value of the use-phase indicator. Hybrid zone-scale decoupling offers a feasible pathway for use-phase decarbonisation without committing to full-floor dry construction.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-07-27
DOI
https://doi.org/10.3390/buildings16152990
Primary Topic
BIM and Construction Integration
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cumulative Intervention Area and Reconfiguration Carbon Intensity: A Comparative LCA of Hybrid Dry Floor Systems in High-Churn Office Buildings

Jusin Park
Buildings
BIM and Construction Integration
article

Cumulative Intervention Area and Reconfiguration Carbon Intensity: A Comparative LCA of Hybrid Dry Floor Systems in High-Churn Office Buildings

Jusin Park
article en

Abstract

Office buildings accumulate embodied carbon not only during construction but repeatedly throughout operation, driven by tenant improvements (TI). In contexts where regulatory and supply-chain constraints limit full design-for-disassembly, this paper explores partial decoupling of a dry slab system within the high-churn zone of a Seoul office. Two area-normalised indicators are introduced—cumulative intervention area (Acum) and Reconfiguration Carbon Intensity (RCI)—defined on the structural slab/panel boundary to complement the mass-weighted Circularity Index (CI). The indicators are demonstrated on a 17-storey Seoul office over 60 years across three scenarios: a wet composite baseline (S1), full-dry CLT (S2), and a hybrid placing CLT within the high-churn zone (S3). S3 reduces RCI by approximately 45% relative to the wet baseline, capturing 71.7% of the full-decoupling benefit while converting only 11.5% of the floor area to CLT—a benefit-to-conversion ratio of 6.2×. Both shares are fixed by the floor-plate geometry, so this ratio is a consequence of the high-churn zone’s concentration rather than an independent empirical finding. A joint-uncertainty stress test confirms that S3 outcomes lie entirely below S1 across plausible parameter ranges. A placement test compares three configurations of the same floor that differ only in CLT placement location relative to the high-churn zone. Mass-weighted CI cannot distinguish these configurations, whereas RCI ranges from no reduction to the full hybrid benefit depending on placement—isolating the diagnostic value of the use-phase indicator. Hybrid zone-scale decoupling offers a feasible pathway for use-phase decarbonisation without committing to full-floor dry construction.

BuildingsVol. 16(15)
Korea University (KR)
Sustainable cities and communities
Openalex Percentile: Top 12%
BIM and Construction Integration
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cumulative Intervention Area and Reconfiguration Carbon Intensity: A Comparative LCA of Hybrid Dry Floor Systems in High-Churn Office Buildings — Jusin Park · Buildings (2026) | TGRS Research Map | TGRS