Axial Flow Check Valve Flow-Field Simulation and Failure Analysis at the Compressor Outlet of a Gas Compressor Station

In long-distance natural gas transmission, installing an axial flow check valve at the compressor outlet of a compressor station helps prevent backflow. Failure of this valve can cause compressor reverse rotation, which disrupts gas delivery. This study models and simulates the steady-state flow field at 100% valve opening and the transient flow features during valve opening and closing. In addition, a failed axial-flow check valve from a natural gas compressor station was disassembled, and initial observations of wear and deformation were used to verify the model. The results show that the maximum fluid velocity reaches 18.9 m/s at 100% valve opening, with a distinct vortex region forming in the throttling passage between the valve seat and disk. During valve opening, the inlet–outlet pressure difference decreases from 0.35 MPa at 0.001 s to 0.20 MPa at 0.080 s. At 60% relative opening, the maximum amplitude of the transient hydrodynamic force fluctuation reaches 662 N. During closure under a pressure difference of 300 kPa, the maximum disk velocity reaches 12.9 m/s. These transient flow and force characteristics, considered together with the wear observed on the guide sleeve and disk, provide insight into the delayed reseating of the valve.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-07-26
DOI
https://doi.org/10.3390/pr14152407
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Flow Check Valve Flow-Field Simulation and Failure Analysis at the Compressor Outlet of a Gas Compressor Station

Xi Zhang, Guotao Nie, Wei Zhong, Ming Zhang
Processes
Refrigeration and Air Conditioning Technologies
article

Axial Flow Check Valve Flow-Field Simulation and Failure Analysis at the Compressor Outlet of a Gas Compressor Station

Xi Zhang, Guotao Nie, Wei Zhong, Ming Zhang
article en

Abstract

In long-distance natural gas transmission, installing an axial flow check valve at the compressor outlet of a compressor station helps prevent backflow. Failure of this valve can cause compressor reverse rotation, which disrupts gas delivery. This study models and simulates the steady-state flow field at 100% valve opening and the transient flow features during valve opening and closing. In addition, a failed axial-flow check valve from a natural gas compressor station was disassembled, and initial observations of wear and deformation were used to verify the model. The results show that the maximum fluid velocity reaches 18.9 m/s at 100% valve opening, with a distinct vortex region forming in the throttling passage between the valve seat and disk. During valve opening, the inlet–outlet pressure difference decreases from 0.35 MPa at 0.001 s to 0.20 MPa at 0.080 s. At 60% relative opening, the maximum amplitude of the transient hydrodynamic force fluctuation reaches 662 N. During closure under a pressure difference of 300 kPa, the maximum disk velocity reaches 12.9 m/s. These transient flow and force characteristics, considered together with the wear observed on the guide sleeve and disk, provide insight into the delayed reseating of the valve.

ProcessesVol. 14(15)
China University of Petroleum, East China (CN), China Classification Society (CN), China National Petroleum Corporation (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 16%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Axial Flow Check Valve Flow-Field Simulation and Failure Analysis at the Compressor Outlet of a Gas Compressor Station — Xi Zhang, Guotao Nie, et al. · Processes (2026) | TGRS Research Map | TGRS