A combined endovascular and ultrasound approach to femoral artery pseudoaneurysm injection following transcatheter aortic valve replacement (TAVR)

Iatrogenic femoral artery pseudoaneurysm (PSA) is a known complication of groin access for endovascular procedures. For cases refractory to ultrasound-guided thrombin injection, open repair risks blood loss during proximal and distal exposure, while covered stenting may be precluded by proximity to the femoral bifurcation. We report an 87-year-old hemodynamically unstable woman on vasopressor support and dual antithrombotic therapy who developed a 2.3-cm wide-necked left common femoral artery PSA during the post-TAVR course. After bedside ultrasound-guided thrombin injection failed, and with both open repair and covered stenting judged high risk, the PSA was treated using a hybrid approach combining endovascular balloon occlusion of the PSA neck with ultrasound-guided thrombin injection. The PSA was successfully excluded with preserved flow in the superficial and deep femoral arteries; 24-hour duplex confirmed a durable seal, and the patient remained complication-free at one year. In high-risk patients with wide-necked PSAs near the femoral bifurcation, this hybrid technique offers a lower-risk alternative to covered stenting or open surgery when standard thrombin injection fails.

Authors

Institutions

Publication Details

Journal
Radiology Case Reports
Published
2026-07-27
DOI
https://doi.org/10.1016/j.radcr.2026.06.138
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A combined endovascular and ultrasound approach to femoral artery pseudoaneurysm injection following transcatheter aortic valve replacement (TAVR)

Jonathan Schor, Viren S. Sehgal, Ajay Menon, Kuldeep Singh
Radiology Case Reports
Vascular Procedures and Complications
article

A combined endovascular and ultrasound approach to femoral artery pseudoaneurysm injection following transcatheter aortic valve replacement (TAVR)

Jonathan Schor, Viren S. Sehgal, Ajay Menon, Kuldeep Singh
article en

Abstract

Iatrogenic femoral artery pseudoaneurysm (PSA) is a known complication of groin access for endovascular procedures. For cases refractory to ultrasound-guided thrombin injection, open repair risks blood loss during proximal and distal exposure, while covered stenting may be precluded by proximity to the femoral bifurcation. We report an 87-year-old hemodynamically unstable woman on vasopressor support and dual antithrombotic therapy who developed a 2.3-cm wide-necked left common femoral artery PSA during the post-TAVR course. After bedside ultrasound-guided thrombin injection failed, and with both open repair and covered stenting judged high risk, the PSA was treated using a hybrid approach combining endovascular balloon occlusion of the PSA neck with ultrasound-guided thrombin injection. The PSA was successfully excluded with preserved flow in the superficial and deep femoral arteries; 24-hour duplex confirmed a durable seal, and the patient remained complication-free at one year. In high-risk patients with wide-necked PSAs near the femoral bifurcation, this hybrid technique offers a lower-risk alternative to covered stenting or open surgery when standard thrombin injection fails.

Radiology Case ReportsVol. 21(10)
Staten Island University Hospital (US)
Good health and well-being
Openalex Percentile: Top 10%
Vascular Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.