Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control

To mitigate active-species flux attenuation and localized treatment blind spots caused by variations in jet-to-surface distance during atmospheric-pressure low-temperature plasma treatment of three-dimensional nonplanar targets, we developed a precision plasma-treatment system integrating machine vision, field-programmable gate array-based trajectory planning, and Z-axis closed-loop laser distance control. The field-programmable gate array handled target-boundary extraction and scan-trajectory generation, while a tilted laser displacement sensor, a spatial geometric compensation model, and a segmented-velocity closed-loop strategy corrected Z-axis deviations in real time and maintained a 10 mm standoff distance. Static tests showed a Z-axis distance-control error of ±0.04 mm, and dynamic step-response tests converged within 500 ms. In a representative scan with repeated ±0.5 mm step disturbances, the measured standoff distance was 10.00 ± 0.18 mm, with an instantaneous range of 9.49–10.52 mm, and the system returned to within ±0.1 mm in approximately 400 ms after each disturbance. Starch-potassium iodide visualization indicated a distance-dependent spatial distribution of plasma-induced oxidative effects. In three independent biological replicates, Escherichia coli plate experiments showed pronounced distance-dependent attenuation in the conventional fixed-height mode, whereas Z-axis closed-loop scanning maintained 99.4%–100.0% sterilization efficiency across all tested regions and geometries. The corresponding log-reduction values, including detection-limit lower bounds for plates with no recovered colonies, were consistent with these results. These findings show that real-time standoff-distance compensation improves treatment uniformity on nonplanar model surfaces and supports the system as a precision plasma-treatment engineering platform for future plasma-medicine studies.

Authors

Institutions

Publication Details

Journal
Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena
Published
2026-07-27
DOI
https://doi.org/10.1116/6.0005538
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control

S Y Wang, Hua Li, Huijuan Lu, Le Dong et al.
Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and Phenomena
Plasma Applications and Diagnostics
article

Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control

S Y Wang, Hua Li, Huijuan Lu, Le Dong, Xiao-Qiong Wang, Zheng-Yan Chen, Xiao-Xia Du, Guang-Xiu Peng
article en

Abstract

To mitigate active-species flux attenuation and localized treatment blind spots caused by variations in jet-to-surface distance during atmospheric-pressure low-temperature plasma treatment of three-dimensional nonplanar targets, we developed a precision plasma-treatment system integrating machine vision, field-programmable gate array-based trajectory planning, and Z-axis closed-loop laser distance control. The field-programmable gate array handled target-boundary extraction and scan-trajectory generation, while a tilted laser displacement sensor, a spatial geometric compensation model, and a segmented-velocity closed-loop strategy corrected Z-axis deviations in real time and maintained a 10 mm standoff distance. Static tests showed a Z-axis distance-control error of ±0.04 mm, and dynamic step-response tests converged within 500 ms. In a representative scan with repeated ±0.5 mm step disturbances, the measured standoff distance was 10.00 ± 0.18 mm, with an instantaneous range of 9.49–10.52 mm, and the system returned to within ±0.1 mm in approximately 400 ms after each disturbance. Starch-potassium iodide visualization indicated a distance-dependent spatial distribution of plasma-induced oxidative effects. In three independent biological replicates, Escherichia coli plate experiments showed pronounced distance-dependent attenuation in the conventional fixed-height mode, whereas Z-axis closed-loop scanning maintained 99.4%–100.0% sterilization efficiency across all tested regions and geometries. The corresponding log-reduction values, including detection-limit lower bounds for plates with no recovered colonies, were consistent with these results. These findings show that real-time standoff-distance compensation improves treatment uniformity on nonplanar model surfaces and supports the system as a precision plasma-treatment engineering platform for future plasma-medicine studies.

Journal of Vacuum Science & Technology B Nanotechnology and Microelectronics Materials Processing Measurement and PhenomenaVol. 44(5)
Guilin University of Electronic Technology (CN)
Natural Science Foundation of Guangxi Zhuang Autonomous Region, National Natural Science Foundation of China, Guilin University of Electronic Technology, National College Students Innovation and Entrepreneurship Training Program
Life in Land
Openalex Percentile: Top 9%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.