Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols

Background/Objectives: This study assesses the outcomes of integrating deep learning-augmented zero echo time (ZTE DL) MRI sequences into standard MRI protocols for assessment of the hands and feet. Methods: In this single-center, retrospective study, a standard MRI protocol of hands and feet at 1.5 T was compared with the same protocol with an added ZTE DL sequence. Pathological changes in the bone, including subcortical sclerosis, osteophytes, joint space narrowing and fractures, were rated as present or absent. Indeterminate intraosseous lesions (erosions/ganglia) and indeterminate extraosseous lesions (ossicles/soft tissue calcifications) were additionally assessed on a semi-quantitative 4-point Likert scale. Diagnostic confidence was rated as low, moderate, or high. Standard MRI vs. ZTE-DL-augmented MRI comparisons were evaluated using a mixed-effects model with reader as a random effect, and X-ray vs. ZTE-DL-augmented MRI comparisons using a paired Wilcoxon signed-rank test. Interreader agreement (two readers) was assessed using Kappa statistics. Results: The cohort encompassed 59 datasets (feet = 22, hands = 37) of 40 patients with an average age of 51.79 (SD ± 11.84) years (58% women (n = 34), 42% men (n = 25)). Additional ZTE DL sequences resulted in similar findings, but with higher diagnostic confidence for assessment of bone changes when compared to conventional MR sequences (p-values < 0.05) and, overall, when compared to radiographs in a subgroup (p < 0.05 for five of six pathologic bone changes). Interreader agreement of diagnostic confidence was moderate to substantial (kappa 0.59–0.71). Conclusions: Addition of ZTE DL sequences to standard MRI protocols of hands and feet at 1.5 T demonstrated similar findings in the assessment of pathological bone changes, but with higher diagnostic confidence compared to conventional MR sequences and radiographs. However, further validation against a reference standard is required to determine diagnostic accuracy.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-07-27
DOI
https://doi.org/10.3390/diagnostics16152363
Primary Topic
Bone and Joint Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols

Malwina Kaniewska, Maélène Lohézic, Roman Guggenberger, Karolina Pawlus et al.
Diagnostics
Bone and Joint Diseases
article

Deep Learning-Augmented Zero Echo Time MRI Increases Diagnostic Confidence for Osseous Assessment in Hand and Foot MRI Protocols

Malwina Kaniewska, Maélène Lohézic, Roman Guggenberger, Karolina Pawlus, Carina Obermüller, Jose de Arcos Rodriguez
article en

Abstract

Background/Objectives: This study assesses the outcomes of integrating deep learning-augmented zero echo time (ZTE DL) MRI sequences into standard MRI protocols for assessment of the hands and feet. Methods: In this single-center, retrospective study, a standard MRI protocol of hands and feet at 1.5 T was compared with the same protocol with an added ZTE DL sequence. Pathological changes in the bone, including subcortical sclerosis, osteophytes, joint space narrowing and fractures, were rated as present or absent. Indeterminate intraosseous lesions (erosions/ganglia) and indeterminate extraosseous lesions (ossicles/soft tissue calcifications) were additionally assessed on a semi-quantitative 4-point Likert scale. Diagnostic confidence was rated as low, moderate, or high. Standard MRI vs. ZTE-DL-augmented MRI comparisons were evaluated using a mixed-effects model with reader as a random effect, and X-ray vs. ZTE-DL-augmented MRI comparisons using a paired Wilcoxon signed-rank test. Interreader agreement (two readers) was assessed using Kappa statistics. Results: The cohort encompassed 59 datasets (feet = 22, hands = 37) of 40 patients with an average age of 51.79 (SD ± 11.84) years (58% women (n = 34), 42% men (n = 25)). Additional ZTE DL sequences resulted in similar findings, but with higher diagnostic confidence for assessment of bone changes when compared to conventional MR sequences (p-values < 0.05) and, overall, when compared to radiographs in a subgroup (p < 0.05 for five of six pathologic bone changes). Interreader agreement of diagnostic confidence was moderate to substantial (kappa 0.59–0.71). Conclusions: Addition of ZTE DL sequences to standard MRI protocols of hands and feet at 1.5 T demonstrated similar findings in the assessment of pathological bone changes, but with higher diagnostic confidence compared to conventional MR sequences and radiographs. However, further validation against a reference standard is required to determine diagnostic accuracy.

DiagnosticsVol. 16(15)
General Electric (Spain) (ES), Kantonsspital Winterthur (CH), University Hospital of Zurich (CH)
Quality Education
Openalex Percentile: Top 8%
Bone and Joint Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.