Design and Experimental Validation of a Multi-output Power Management Unit for a Multiple-particles Analyzer under Dynamic-load and Thermal-vacuum Conditions

Sensors and Materials, Vol. 38, No. 7 (2026) power densities and long-duration mission operations in space applications.Beyond power conversion, the PMU embeds on-board voltage, current, and temperature sensing for real-time health monitoring; this integrated telemetry not only safeguards the particle-sensing MPA payload but also provides a continuous data stream that can underpin Artificial Intelligence of Things (AIoT) and intelligent-sensing functions such as autonomous fault diagnosis and predictive maintenance.The PMU integrates on-board temperature (MCP9700) and voltage/ current sensing for real-time health monitoring, and its thermal behavior was further characterized through multi-point temperature sensing during thermal-vacuum testing.As the enabling and protection unit for the MPA-a particle-sensing payload-the PMU, together with the payload, was additionally subjected to proton single-event-effect and 60 Co total-ionizingdose radiation testing to verify its reliability in the space environment.

Authors

Publication Details

Journal
Sensors and Materials
Published
2026-07-27
DOI
https://doi.org/10.18494/sam6042
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Experimental Validation of a Multi-output Power Management Unit for a Multiple-particles Analyzer under Dynamic-load and Thermal-vacuum Conditions

Cheng‐Chi Tai, Yung‐Tsung Cheng, Yu-Rong Cheng, Tzu-Fang Chang et al.
Sensors and Materials
Scientific Measurement and Uncertainty Evaluation
article

Design and Experimental Validation of a Multi-output Power Management Unit for a Multiple-particles Analyzer under Dynamic-load and Thermal-vacuum Conditions

Cheng‐Chi Tai, Yung‐Tsung Cheng, Yu-Rong Cheng, Tzu-Fang Chang, Chih-Yu Chiang
article en

Abstract

Sensors and Materials, Vol. 38, No. 7 (2026) power densities and long-duration mission operations in space applications.Beyond power conversion, the PMU embeds on-board voltage, current, and temperature sensing for real-time health monitoring; this integrated telemetry not only safeguards the particle-sensing MPA payload but also provides a continuous data stream that can underpin Artificial Intelligence of Things (AIoT) and intelligent-sensing functions such as autonomous fault diagnosis and predictive maintenance.The PMU integrates on-board temperature (MCP9700) and voltage/ current sensing for real-time health monitoring, and its thermal behavior was further characterized through multi-point temperature sensing during thermal-vacuum testing.As the enabling and protection unit for the MPA-a particle-sensing payload-the PMU, together with the payload, was additionally subjected to proton single-event-effect and 60 Co total-ionizingdose radiation testing to verify its reliability in the space environment.

Sensors and MaterialsVol. 38(7)
Affordable and clean energy
Openalex Percentile: Top 7%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Experimental Validation of a Multi-output Power Management Unit for a Multiple-particles Analyzer under Dynamic-load and Thermal-vacuum Conditions — Cheng‐Chi Tai, Yung‐Tsung Cheng, et al. · Sensors and Materials (2026) | TGRS Research Map | TGRS