Transient FSI–Fatigue Coupling Analysis of a Francis Turbine Runner Under Load Rejection

With increasing renewable energy penetration, hydropower units face more frequent load rejection transients, which impose severe hydraulic excitation on Francis turbine runners. Although extensive studies have investigated flow dynamics and stress concentrations during transients, quantitative fatigue damage assessments for runners with pre-existing cracks remain scarce. To fill this gap, this study conducts CFD simulations coupled with one-way FSI to analyze a Francis turbine runner during load rejection, comparing uncracked and cracked configurations. Fatigue damage is evaluated using rain-flow counting, a modified S-N curve with Goodman mean stress correction, and the Palmgren–Miner linear damage rule. Results show that stress concentrations shift from the band-side to the crown-side T-junction during load rejection, with 4.5 times higher fatigue damage at the crown (D = 1.62 × 10−4) than at the band (D = 3.57 × 10−5). Pre-existing cracks increase local stress and reduce the allowable number of load rejection events from 6173 to 514 cycles. Reducing residual stress from 200 MPa to 100 MPa lowers fatigue damage by approximately 42%. This study provides a quantitative framework for transient fatigue assessments.

Authors

Institutions

Publication Details

Journal
Machines
Published
2026-07-27
DOI
https://doi.org/10.3390/machines14080848
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient FSI–Fatigue Coupling Analysis of a Francis Turbine Runner Under Load Rejection

Ma Min, Yi Luo, Alexandre Presas, Zequan Zhang et al.
Machines
Cavitation Phenomena in Pumps
article

Transient FSI–Fatigue Coupling Analysis of a Francis Turbine Runner Under Load Rejection

Ma Min, Yi Luo, Alexandre Presas, Zequan Zhang, Ruiwen Ren, Yonggang Lu, Chengming Liu
article en

Abstract

With increasing renewable energy penetration, hydropower units face more frequent load rejection transients, which impose severe hydraulic excitation on Francis turbine runners. Although extensive studies have investigated flow dynamics and stress concentrations during transients, quantitative fatigue damage assessments for runners with pre-existing cracks remain scarce. To fill this gap, this study conducts CFD simulations coupled with one-way FSI to analyze a Francis turbine runner during load rejection, comparing uncracked and cracked configurations. Fatigue damage is evaluated using rain-flow counting, a modified S-N curve with Goodman mean stress correction, and the Palmgren–Miner linear damage rule. Results show that stress concentrations shift from the band-side to the crown-side T-junction during load rejection, with 4.5 times higher fatigue damage at the crown (D = 1.62 × 10−4) than at the band (D = 3.57 × 10−5). Pre-existing cracks increase local stress and reduce the allowable number of load rejection events from 6173 to 514 cycles. Reducing residual stress from 200 MPa to 100 MPa lowers fatigue damage by approximately 42%. This study provides a quantitative framework for transient fatigue assessments.

MachinesVol. 14(8)
Jiangsu University (CN), Shanghai Power Equipment Research Institute (CN), Universitat Politècnica de Catalunya (ES), Tsinghua University (CN)
National Natural Science Foundation of China, China Yangtze Power
Affordable and clean energy
Openalex Percentile: Top 15%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.