Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography

Background and Objective: Accurate extraction of respiratory diaphragmatic electromyography (dEMG) is hindered by electrocardiographic (ECG) interference, motion artifacts, and noise. Existing methods, although effective, may remove physiologically relevant information. To enable robust ECG and artifact suppression while maintaining respiratory-related amplitude variations, a higher-order singular value decomposition (HO-SVD) based approach was developed. Methods: The HO-SVD algorithm exploits the multidimensional structure of dEMG recordings by jointly decomposing the temporal, overlapped QRS complexes, and spatial (channel) dimensions. The method enables targeted suppression of coherent and repetitive artifacts prior to signal reconstruction. Performance was evaluated on three synthetic datasets and on clinical data from ten patients with obstructive sleep apnea, using a previously developed two-dimensional SVD algorithm (SVD RI ) as a reference. Results: Across synthetic datasets, HO-SVD consistently outperformed SVD RI in all evaluation metrics. In clean conditions, HO-SVD improved the median signal-to-noise ratio (SNR) by 27 dB (131%) relative to the original signal. In datasets with mild motion artifacts and complex muscle interference, median SNR improvements of up to 19 dB (88%) were observed. The symmetric mean absolute error and mean frequency deviation were significantly lower for HO-SVD across all input SNRs ( p < 0.0001 ) compared to SVD RI . In clinical data, HO-SVD achieved a significantly higher correlation with reference esophageal pressure ( p < 0.02 ), greater ECG suppression ( p < 0.0001 ), and fewer outliers ( p < 0.0001 ) than SVD RI . Conclusion: These results demonstrate that incorporating a third (spatial) dimension and adaptive thresholding across tensor modes enables robust removal of ECG interference and motion artifacts while preserving respiratory dEMG modulation. The proposed HO-SVD framework offers a flexible and effective approach for multichannel biomedical signal denoising.

Authors

Institutions

Publication Details

Journal
Computer Methods and Programs in Biomedicine
Published
2026-07-27
DOI
https://doi.org/10.1016/j.cmpb.2026.109559
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography

Elisabetta Peri, Massimo Mischi, Sebastiaan Overeem, Xi Long et al.
Computer Methods and Programs in Biomedicine
Non-Invasive Vital Sign Monitoring
article

Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography

Elisabetta Peri, Massimo Mischi, Sebastiaan Overeem, Xi Long, J. Dijk, Gabriela M. Grońska
article en

Abstract

Background and Objective: Accurate extraction of respiratory diaphragmatic electromyography (dEMG) is hindered by electrocardiographic (ECG) interference, motion artifacts, and noise. Existing methods, although effective, may remove physiologically relevant information. To enable robust ECG and artifact suppression while maintaining respiratory-related amplitude variations, a higher-order singular value decomposition (HO-SVD) based approach was developed. Methods: The HO-SVD algorithm exploits the multidimensional structure of dEMG recordings by jointly decomposing the temporal, overlapped QRS complexes, and spatial (channel) dimensions. The method enables targeted suppression of coherent and repetitive artifacts prior to signal reconstruction. Performance was evaluated on three synthetic datasets and on clinical data from ten patients with obstructive sleep apnea, using a previously developed two-dimensional SVD algorithm (SVD RI ) as a reference. Results: Across synthetic datasets, HO-SVD consistently outperformed SVD RI in all evaluation metrics. In clean conditions, HO-SVD improved the median signal-to-noise ratio (SNR) by 27 dB (131%) relative to the original signal. In datasets with mild motion artifacts and complex muscle interference, median SNR improvements of up to 19 dB (88%) were observed. The symmetric mean absolute error and mean frequency deviation were significantly lower for HO-SVD across all input SNRs ( p < 0.0001 ) compared to SVD RI . In clinical data, HO-SVD achieved a significantly higher correlation with reference esophageal pressure ( p < 0.02 ), greater ECG suppression ( p < 0.0001 ), and fewer outliers ( p < 0.0001 ) than SVD RI . Conclusion: These results demonstrate that incorporating a third (spatial) dimension and adaptive thresholding across tensor modes enables robust removal of ECG interference and motion artifacts while preserving respiratory dEMG modulation. The proposed HO-SVD framework offers a flexible and effective approach for multichannel biomedical signal denoising.

Computer Methods and Programs in BiomedicineVol. 286
Kempenhaeghe (NL), Eindhoven University of Technology (NL)
Technische Universiteit Eindhoven
Openalex Percentile: Top 17%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.