Fire spread between balconies with exposed timber decks for the fire risk appraisal of external walls
This article examines fire spread between cantilevered balconies incorporating exposed timber decking, with relevance to fire risk appraisals of external walls laid out in PAS 9980. The analysis considers heat release rate, visual observations and heat flux measurements from full-scale balcony fire tests. The findings indicate that exposed timber decking can contribute to fire growth once ignited, and that gaps between decking boards may permit flame penetration and promote the ignition of combustible items on upper balconies. A thermal radiation model is proposed to relate balcony depth, length and storey-to-storey separation to the heat flux received by an upper balcony, using a critical heat flux criterion for ignition. The results support the PAS 9980 view that exposed timber balcony decks tend towards a negative risk factor, although balconies of a defined limited extent of 2 m wide by 1 m deep may be treated as neutral within a wider risk appraisal context.
Authors
- Danny Hopkin (ORCID: https://orcid.org/0000-0002-2559-3581)
- Konstantinos E. Chotzoglou (ORCID: https://orcid.org/0000-0002-2775-0384)
- Michael Spearpoint (ORCID: https://orcid.org/0000-0002-3632-4870)
Institutions
- OFR Consultants (United Kingdom) (GB)
Publication Details
- Journal
- Journal of Fire Sciences
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1177/07349041261501962
- Primary Topic
- Fire dynamics and safety research
- Type
- article
- Field-Weighted Citation Impact
- 0.00