VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR

BACKGROUND: Murray law-based quantitative flow ratio (μQFR) is an angiography-derived physiological index that utilizes a single angiographic projection with artificial intelligence-guided vessel segmentation. AIMS: To evaluate the diagnostic accuracy and time efficacy of 2D-μQFR against wire-based fractional flow reserve (FFR ≤ 0.80), compare its performance with 3D-μQFR and vessel-FFR (vFFR), and assess feasibility in lesions excluded from vFFR analysis. METHODS: This sub-study of the prospective VERMONT trial analyzed 2D- and 3D-μQFR retrospectively using prospectively acquired angiograms, with wire-based FFR as the reference standard. RESULTS: Among 209 patients with 225 intermediate lesions, 205 lesions were analyzed. 2D-μQFR demonstrated excellent diagnostic accuracy for FFR ≤ 0.80 (AUC 0.95; 95% CI 0.93-0.98), with 93% sensitivity, 92% specificity, 88% positive predictive value (PPV), and 95% negative predictive value (NPV). Inter-observer agreement was excellent (r = 0.94, p < 0.001), and 2D-μQFR analysis was 15.1 min faster than wire-based FFR (1.8 ± 0.7 vs. 16.9 ± 5.4 min, p < 0.001). Diagnostic performance was comparable to that of 3D-μQFR, which achieved an AUC of 0.94 (95% CI 0.91-0.97), with 89% sensitivity, 90% specificity, 86% PPV, and 93% NPV. It was more specific than vFFR, which achieved an AUC of 0.92 (95% CI 0.89-0.96), with 90% sensitivity, 79% specificity, 74% PPV, and 93% NPV. Single-projection analysis was feasible in 85% of lesions excluded from vFFR due to image quality limitations. CONCLUSION: Single-projection 2D-μQFR provides accurate, rapid, and reproducible physiological assessment comparable to 3D-μQFR with superior specificity to vFFR. These findings support 2D-μQFR as a practical, wire-free alternative to invasive FFR in routine clinical practice.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-07-27
DOI
https://doi.org/10.1002/ccd.70768
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR

D. Akrawi, Jim Basilakis, U. Premawardhana, K. Soosapilla et al.
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR

D. Akrawi, Jim Basilakis, U. Premawardhana, K. Soosapilla, Justyn Huang, Giuseppe Femia, Aiden OLoughlin, Hennessy Av, Phong T D Nguyen, Tamer Yousef Naguib Badie, Sidney Lo, Hao Tran, J F Xu, Oliver Gibbs, Hashim Kachwalla, Krishna Kadappu, Rahul Kurup
article en

Abstract

BACKGROUND: Murray law-based quantitative flow ratio (μQFR) is an angiography-derived physiological index that utilizes a single angiographic projection with artificial intelligence-guided vessel segmentation. AIMS: To evaluate the diagnostic accuracy and time efficacy of 2D-μQFR against wire-based fractional flow reserve (FFR ≤ 0.80), compare its performance with 3D-μQFR and vessel-FFR (vFFR), and assess feasibility in lesions excluded from vFFR analysis. METHODS: This sub-study of the prospective VERMONT trial analyzed 2D- and 3D-μQFR retrospectively using prospectively acquired angiograms, with wire-based FFR as the reference standard. RESULTS: Among 209 patients with 225 intermediate lesions, 205 lesions were analyzed. 2D-μQFR demonstrated excellent diagnostic accuracy for FFR ≤ 0.80 (AUC 0.95; 95% CI 0.93-0.98), with 93% sensitivity, 92% specificity, 88% positive predictive value (PPV), and 95% negative predictive value (NPV). Inter-observer agreement was excellent (r = 0.94, p < 0.001), and 2D-μQFR analysis was 15.1 min faster than wire-based FFR (1.8 ± 0.7 vs. 16.9 ± 5.4 min, p < 0.001). Diagnostic performance was comparable to that of 3D-μQFR, which achieved an AUC of 0.94 (95% CI 0.91-0.97), with 89% sensitivity, 90% specificity, 86% PPV, and 93% NPV. It was more specific than vFFR, which achieved an AUC of 0.92 (95% CI 0.89-0.96), with 90% sensitivity, 79% specificity, 74% PPV, and 93% NPV. Single-projection analysis was feasible in 85% of lesions excluded from vFFR due to image quality limitations. CONCLUSION: Single-projection 2D-μQFR provides accurate, rapid, and reproducible physiological assessment comparable to 3D-μQFR with superior specificity to vFFR. These findings support 2D-μQFR as a practical, wire-free alternative to invasive FFR in routine clinical practice.

Catheterization and Cardiovascular Interventions
Camden and Campbelltown Hospitals (AU), The University of Sydney (AU), Liverpool Hospital (AU), UNSW Sydney (AU), Western Sydney University (AU)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.