Agreement Between Tear Film Tests Performed by Novice Examiners

PURPOSE: To explore the agreement among tear break-up time measurements performed by novice examiners using manual non-invasive tear break-up time (mNIBUT), automated non-invasive tear break-up time (aNIBUT) and fluorescein tear break-up time (FBUT), and to examine the association between tear film metrics and symptoms. METHODS: A total of 61 volunteers (44 females) with a mean age of 21.5 ± 2.7 years underwent tear-film assessment performed by novice examiners (undergraduate students). The tear volume (Schirmer test), tear film stability by mNIBUT, aNIBUT and FBUT, along with lipid layer pattern, were assessed. Symptoms associated with tear-film quality and ocular surface discomfort were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. RESULTS: Normal values were seen in 88.5%, 93.4%, 73.8% and 39.3% of participants using the Schirmer test, FBUT, mNIBUT and aNIBUT, respectively. The intraclass correlation coefficient (ICC) for tear break-up measurements indicated poor reliability between tests, except when comparing mNIBUT and FBUT (ICC = 0.67 and 0.60 for averaged and first measurements, respectively). Bland-Altman analysis showed that the 95% limits of agreement for mNIBUT-aNIBUT and FBUT-aNIBUT were wider than those for FBUT-mNIBUT. The lack of agreement did not change when averaging the three measurements. Results from the OSDI indicated that most participants did not report symptoms. No significant correlations were observed between the OSDI total score and any of the tear metrics (p > 0.05). The aNIBUT demonstrated the best agreement with symptoms in this young and largely asymptomatic population. CONCLUSIONS: Tear break-up time measurements obtained by novice examiners showed limited reliability and agreement when comparing traditional methods (FBUT and mNIBUT) and the aNIBUT. Examiner-related variability may influence the assessment of tear-film stability, although causal inferences regarding examiner experience cannot be established from this study design. Repeating measurements did not improve the reliability and agreement between tests when performed by novice examiners.

Authors

Institutions

Publication Details

Journal
Ophthalmic and Physiological Optics
Published
2026-07-27
DOI
https://doi.org/10.1007/s44402-026-00152-x
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement Between Tear Film Tests Performed by Novice Examiners

Rosario G. Anera, Miriam Casares‐López, Sonia Ortiz‐Peregrina, Francesco Martino et al.
Ophthalmic and Physiological Optics
Ocular Surface and Contact Lens
article

Agreement Between Tear Film Tests Performed by Novice Examiners

Rosario G. Anera, Miriam Casares‐López, Sonia Ortiz‐Peregrina, Francesco Martino, Pilar Granados‐Delgado, Miriam Carrillo-Pulido
article en

Abstract

PURPOSE: To explore the agreement among tear break-up time measurements performed by novice examiners using manual non-invasive tear break-up time (mNIBUT), automated non-invasive tear break-up time (aNIBUT) and fluorescein tear break-up time (FBUT), and to examine the association between tear film metrics and symptoms. METHODS: A total of 61 volunteers (44 females) with a mean age of 21.5 ± 2.7 years underwent tear-film assessment performed by novice examiners (undergraduate students). The tear volume (Schirmer test), tear film stability by mNIBUT, aNIBUT and FBUT, along with lipid layer pattern, were assessed. Symptoms associated with tear-film quality and ocular surface discomfort were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. RESULTS: Normal values were seen in 88.5%, 93.4%, 73.8% and 39.3% of participants using the Schirmer test, FBUT, mNIBUT and aNIBUT, respectively. The intraclass correlation coefficient (ICC) for tear break-up measurements indicated poor reliability between tests, except when comparing mNIBUT and FBUT (ICC = 0.67 and 0.60 for averaged and first measurements, respectively). Bland-Altman analysis showed that the 95% limits of agreement for mNIBUT-aNIBUT and FBUT-aNIBUT were wider than those for FBUT-mNIBUT. The lack of agreement did not change when averaging the three measurements. Results from the OSDI indicated that most participants did not report symptoms. No significant correlations were observed between the OSDI total score and any of the tear metrics (p > 0.05). The aNIBUT demonstrated the best agreement with symptoms in this young and largely asymptomatic population. CONCLUSIONS: Tear break-up time measurements obtained by novice examiners showed limited reliability and agreement when comparing traditional methods (FBUT and mNIBUT) and the aNIBUT. Examiner-related variability may influence the assessment of tear-film stability, although causal inferences regarding examiner experience cannot be established from this study design. Repeating measurements did not improve the reliability and agreement between tests when performed by novice examiners.

Ophthalmic and Physiological Optics
Universidad de Granada (ES)
Universidad de Granada, Agencia Estatal de Investigación
Openalex Percentile: Top 7%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.