Artificial intelligence in prostate MRI: Comparative diagnostic performance in a high-prevalence cohort

Background Artificial intelligence (AI) is increasingly used in prostate cancer diagnostic workflows but remains insufficiently validated in high-prevalence cohorts often encountered in academic referral centers. Purpose To compare the diagnostic performance of licensed AI software with routine radiologist readings of prostate MRI, using histopathology as the reference standard. Material and Methods In this retrospective study, 1000 patients underwent prostate MRI for suspected prostate cancer (between May 2020 and December 2024), followed by transperineal biopsy; 391 subsequently underwent radical prostatectomy. Diagnostic performance was assessed using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy across PI-RADS thresholds. Receiver operating characteristic (ROC) analysis, Cohen's kappa for inter-rater agreement, and paired McNemar's test were performed. Results In total, 959 patients (mean age = 69.7 ± 8.4 years) were included; clinically significant prostate cancer (csPCa) was found in 830 (86.5%) patients. AI assigned more cases to PI-RADS 1–2 and fewer to PI-RADS 3 (κ = 0.388; P <.001). At the PI-RADS ≥3 threshold, radiologists showed sensitivity 96.0%, specificity 20.9%, accuracy 85.9%, PPV 88.7%, and NPV 45.0%, compared with 91.3%, 37.2%, 84.0%, 90.3%, and 40.0% for AI ( P <.001). ROC performance was comparable (AUC 0.763 vs. 0.739; P = .28). In the prostatectomy subgroup, AI demonstrated a higher false-negative rate (8.4% vs. 4.1%; odds ratio = 3.83, 95% confidence interval [CI] = 1.52–11.51). Conclusion AI showed diagnostic performance comparable to that of radiologists for csPCa detection, with no significant difference in AUC. AI reduced indeterminate PI-RADS 3 scores but missed more significant cancers.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2026-07-27
DOI
https://doi.org/10.1177/02841851261470455
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence in prostate MRI: Comparative diagnostic performance in a high-prevalence cohort

Stig Müller, Kjell‐Inge Gjesdal, Ingrid Framås Syversen, Jonn Terje Geitung et al.
Acta Radiologica
Prostate Cancer Diagnosis and Treatment
article

Artificial intelligence in prostate MRI: Comparative diagnostic performance in a high-prevalence cohort

Stig Müller, Kjell‐Inge Gjesdal, Ingrid Framås Syversen, Jonn Terje Geitung, Jan Oldenburg, Owen Thomas, Anders Christian Hansen, Nádia Gonçalves Ferreira
article en

Abstract

Background Artificial intelligence (AI) is increasingly used in prostate cancer diagnostic workflows but remains insufficiently validated in high-prevalence cohorts often encountered in academic referral centers. Purpose To compare the diagnostic performance of licensed AI software with routine radiologist readings of prostate MRI, using histopathology as the reference standard. Material and Methods In this retrospective study, 1000 patients underwent prostate MRI for suspected prostate cancer (between May 2020 and December 2024), followed by transperineal biopsy; 391 subsequently underwent radical prostatectomy. Diagnostic performance was assessed using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy across PI-RADS thresholds. Receiver operating characteristic (ROC) analysis, Cohen's kappa for inter-rater agreement, and paired McNemar's test were performed. Results In total, 959 patients (mean age = 69.7 ± 8.4 years) were included; clinically significant prostate cancer (csPCa) was found in 830 (86.5%) patients. AI assigned more cases to PI-RADS 1–2 and fewer to PI-RADS 3 (κ = 0.388; P <.001). At the PI-RADS ≥3 threshold, radiologists showed sensitivity 96.0%, specificity 20.9%, accuracy 85.9%, PPV 88.7%, and NPV 45.0%, compared with 91.3%, 37.2%, 84.0%, 90.3%, and 40.0% for AI ( P <.001). ROC performance was comparable (AUC 0.763 vs. 0.739; P = .28). In the prostatectomy subgroup, AI demonstrated a higher false-negative rate (8.4% vs. 4.1%; odds ratio = 3.83, 95% confidence interval [CI] = 1.52–11.51). Conclusion AI showed diagnostic performance comparable to that of radiologists for csPCa detection, with no significant difference in AUC. AI reduced indeterminate PI-RADS 3 scores but missed more significant cancers.

Acta Radiologica
University of Oslo (NO), University of Cambridge (GB), Akershus University Hospital (NO), Ålesund Hospital (NO)
Quality Education
Openalex Percentile: Top 10%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.