Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry

A CT-80 coiled tubing fractured at the gooseneck during retrieval after a 2.5 h treatment with 15% HCl under high-temperature bottom-hole conditions (196 °C). The failure was investigated by dimensional measurements, metallography, Vickers microhardness testing, SEM/EDS, and FT-IR spectroscopy. Pronounced corrosion asymmetry was observed. Cumulative external wall loss reached 1.196 mm, compared with 0.292 mm on the inner wall, while the wall loss attributed to the final operation was approximately twelve times greater externally than internally. These findings suggest two different exposure histories: predominantly uniform attack of the outer wall during backflow of spent, inhibitor-depleted acid, and localized pitting of the inner wall under incomplete inhibitor coverage. EDS mapping identified Sb-rich deposits around inner-wall pits. In combination with the relevant literature, this distribution is consistent with a possible Sb–Fe galvanic effect that may have promoted local anodic dissolution, although galvanic coupling was not measured directly. The FT-IR spectra were consistent with iron oxides/oxyhydroxides, carbonate-containing scale, sulfate-bearing products on the outer surface, and thin organic residues rather than a continuous inhibitor film. Microhardness increased from 229 HV1 in the new tubing to 243.4 HV1 at the fracture location; this increase may reflect limited hydrogen uptake together with service-induced strain hardening or residual stresses. Fractography showed necking and dimpled microvoid coalescence, supporting a predominantly ductile overload mechanism in the corrosion-thinned section. A limited contribution of hydrogen to ductility loss cannot be excluded because the hydrogen content was not quantified.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-07-27
DOI
https://doi.org/10.3390/ma19153200
Primary Topic
Hydrogen embrittlement and corrosion behaviors in metals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry

Vedrana Špada, Lovro Liverić, Marko Kršulja, Damir Karabaić
Materials
Hydrogen embrittlement and corrosion behaviors in metals
article

Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry

Vedrana Špada, Lovro Liverić, Marko Kršulja, Damir Karabaić
article en

Abstract

A CT-80 coiled tubing fractured at the gooseneck during retrieval after a 2.5 h treatment with 15% HCl under high-temperature bottom-hole conditions (196 °C). The failure was investigated by dimensional measurements, metallography, Vickers microhardness testing, SEM/EDS, and FT-IR spectroscopy. Pronounced corrosion asymmetry was observed. Cumulative external wall loss reached 1.196 mm, compared with 0.292 mm on the inner wall, while the wall loss attributed to the final operation was approximately twelve times greater externally than internally. These findings suggest two different exposure histories: predominantly uniform attack of the outer wall during backflow of spent, inhibitor-depleted acid, and localized pitting of the inner wall under incomplete inhibitor coverage. EDS mapping identified Sb-rich deposits around inner-wall pits. In combination with the relevant literature, this distribution is consistent with a possible Sb–Fe galvanic effect that may have promoted local anodic dissolution, although galvanic coupling was not measured directly. The FT-IR spectra were consistent with iron oxides/oxyhydroxides, carbonate-containing scale, sulfate-bearing products on the outer surface, and thin organic residues rather than a continuous inhibitor film. Microhardness increased from 229 HV1 in the new tubing to 243.4 HV1 at the fracture location; this increase may reflect limited hydrogen uptake together with service-induced strain hardening or residual stresses. Fractography showed necking and dimpled microvoid coalescence, supporting a predominantly ductile overload mechanism in the corrosion-thinned section. A limited contribution of hydrogen to ductility loss cannot be excluded because the hydrogen content was not quantified.

MaterialsVol. 19(15)
Juraj Dobrila University of Pula (HR)
Openalex Percentile: Top 21%
Hydrogen embrittlement and corrosion behaviors in metals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.