Stability of Ruthenium Oxide Coated Microelectrode Arrays for Chronic Stimulation of Rat Somatosensory Cortex

Intracortical microstimulation (ICMS) of the primary somatosensory cortex offers the potential for restoring sensory function in neuroprosthetic applications; however, achieving stable long-term performance from implanted electrode materials remains a challenge. Recently, ruthenium oxide (RuO x ) has emerged as a viable faradaic coating material suitable for ICMS application due to its high charge injection capacity, low impedance, and stable electrochemical properties. However, its long-term in vivo performance remains an area of active investigation. In this study, we evaluated the viability of RuO x -coated amorphous silicon carbide microelectrode arrays (MEAs) for producing ICMS-evoked percepts over a 25-week chronic implantation period with an established rodent-based go/no-go behavioral paradigm. Weekly behavioral, electrochemical, and local electrophysiological measurements were analyzed to assess the stability of RuO x for long-term stimulation and recording studies. Results showed an exponential-like reduction in perception thresholds, stabilizing around the ninth post-implantation week at ~0.4 nC/ph per electrode ×16 electrodes (simultaneous multi-channel stimulation). Throughout this period, behavioral performance remained consistently high (~91%), with stable reaction times, indicating reliable sensory perception up to 25 weeks. Electrochemical measurements, including 1 kHz impedance and driving voltage, alongside neural recording metrics like spike rate and noise floor, remained relatively stable throughout the study. Although minor degradations in the number of detected units per electrode and the peak-to-peak voltages of those units were observed (consistent with other silicon-based MEA studies), RuO x -coated electrodes demonstrated the ability to reliably evoke sensory percepts over the duration of the experiment. Overall, these findings highlight RuO x as a durable MEA-coating material for future ICMS applications.

Authors

Institutions

Publication Details

Journal
Journal of Neurophysiology
Published
2026-07-27
DOI
https://doi.org/10.1152/jn.00047.2026
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability of Ruthenium Oxide Coated Microelectrode Arrays for Chronic Stimulation of Rat Somatosensory Cortex

Joseph J. Pancrazio, Claire Cheon, Arlin A. Khan, Stuart F. Cogan et al.
Journal of Neurophysiology
Neuroscience and Neural Engineering
article

Stability of Ruthenium Oxide Coated Microelectrode Arrays for Chronic Stimulation of Rat Somatosensory Cortex

Joseph J. Pancrazio, Claire Cheon, Arlin A. Khan, Stuart F. Cogan, Ghazaal Tahmasebi, Ana G. Hernández-Reynoso, Thomas J. Smith, Madison S. Jiang, Fareeha Faruk, Mihai Bendea, Shreya Tirumala Kumara, Mahasty Khajehzadeh, Luisa R Villafranca, Ashlynn Ogundipe, Sophia L. Vargas, Justin Abbott, Eleanor N. Jeakle, Mehak Kaul, Hari Srinivasan, Andrew Barre
article en

Abstract

Intracortical microstimulation (ICMS) of the primary somatosensory cortex offers the potential for restoring sensory function in neuroprosthetic applications; however, achieving stable long-term performance from implanted electrode materials remains a challenge. Recently, ruthenium oxide (RuO x ) has emerged as a viable faradaic coating material suitable for ICMS application due to its high charge injection capacity, low impedance, and stable electrochemical properties. However, its long-term in vivo performance remains an area of active investigation. In this study, we evaluated the viability of RuO x -coated amorphous silicon carbide microelectrode arrays (MEAs) for producing ICMS-evoked percepts over a 25-week chronic implantation period with an established rodent-based go/no-go behavioral paradigm. Weekly behavioral, electrochemical, and local electrophysiological measurements were analyzed to assess the stability of RuO x for long-term stimulation and recording studies. Results showed an exponential-like reduction in perception thresholds, stabilizing around the ninth post-implantation week at ~0.4 nC/ph per electrode ×16 electrodes (simultaneous multi-channel stimulation). Throughout this period, behavioral performance remained consistently high (~91%), with stable reaction times, indicating reliable sensory perception up to 25 weeks. Electrochemical measurements, including 1 kHz impedance and driving voltage, alongside neural recording metrics like spike rate and noise floor, remained relatively stable throughout the study. Although minor degradations in the number of detected units per electrode and the peak-to-peak voltages of those units were observed (consistent with other silicon-based MEA studies), RuO x -coated electrodes demonstrated the ability to reliably evoke sensory percepts over the duration of the experiment. Overall, these findings highlight RuO x as a durable MEA-coating material for future ICMS applications.

Journal of Neurophysiology
The University of Texas at Dallas (US), Case Western Reserve University (US)
Eugene McDermott Foundation, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 14%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.