Innovations in glaucoma treatment: development and testing of a novel self-adjustable implant for effective pressure regulation

Glaucoma drainage devices (GDDs) are widely used to lower intraocular pressure (IOP) and slow disease progression; however, existing designs often lack intrinsic protection against early postoperative hypotony, show limited adaptability to evolving distal outflow resistance during bleb maturation, and rely on bulky or complex components that constrain implantation and MRI compatibility. Here, we present a compact, fully passive, self-adjustable glaucoma implant designed to maintain IOP within the physiological range by dynamically modulating its hydraulic resistance without external control or postoperative adjustment. The device consists of a circular microvalve incorporating a thin, pre-stressed compliant membrane that responds to pressure conditions at the inlet and outlet. Valve performance was investigated using fully coupled fluid-structure interaction (FSI) simulations and parametric analyses, followed by fabrication and in vitro characterization, and ex vivo assessment of surgical feasibility in enucleated porcine eyes. The results demonstrate effective pressure regulation across physiologically relevant conditions, with mitigation of early hypotony and attenuation of pressure elevation under increasing downstream resistance. Ex vivo implantation confirmed ease of placement, appropriate anatomical fit, and compatibility with standard surgical workflows. Owing to its compact form factor, passive operation, and simplified, cost-effective design, the proposed implant addresses key limitations of current GDDs and shows strong potential for clinical translation.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2026-07-27
DOI
https://doi.org/10.1038/s41378-026-01400-3
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovations in glaucoma treatment: development and testing of a novel self-adjustable implant for effective pressure regulation

Nikolaos Stergiopulos, Constantinos Stergiopulos, Adan Villamarin, Stéphane Bigler et al.
Microsystems & Nanoengineering
Glaucoma and retinal disorders
article

Innovations in glaucoma treatment: development and testing of a novel self-adjustable implant for effective pressure regulation

Nikolaos Stergiopulos, Constantinos Stergiopulos, Adan Villamarin, Stéphane Bigler, Soroush Rafiei, Julien Maxime Gerber
article en

Abstract

Glaucoma drainage devices (GDDs) are widely used to lower intraocular pressure (IOP) and slow disease progression; however, existing designs often lack intrinsic protection against early postoperative hypotony, show limited adaptability to evolving distal outflow resistance during bleb maturation, and rely on bulky or complex components that constrain implantation and MRI compatibility. Here, we present a compact, fully passive, self-adjustable glaucoma implant designed to maintain IOP within the physiological range by dynamically modulating its hydraulic resistance without external control or postoperative adjustment. The device consists of a circular microvalve incorporating a thin, pre-stressed compliant membrane that responds to pressure conditions at the inlet and outlet. Valve performance was investigated using fully coupled fluid-structure interaction (FSI) simulations and parametric analyses, followed by fabrication and in vitro characterization, and ex vivo assessment of surgical feasibility in enucleated porcine eyes. The results demonstrate effective pressure regulation across physiologically relevant conditions, with mitigation of early hypotony and attenuation of pressure elevation under increasing downstream resistance. Ex vivo implantation confirmed ease of placement, appropriate anatomical fit, and compatibility with standard surgical workflows. Owing to its compact form factor, passive operation, and simplified, cost-effective design, the proposed implant addresses key limitations of current GDDs and shows strong potential for clinical translation.

Microsystems & NanoengineeringVol. 12(1)
École Polytechnique Fédérale de Lausanne (CH)
École Polytechnique Fédérale de Lausanne, Servier
Good health and well-being
Openalex Percentile: Top 7%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Innovations in glaucoma treatment: development and testing of a novel self-adjustable implant for effective pressure regulation — Nikolaos Stergiopulos, Constantinos Stergiopulos, et al. · Microsystems & Nanoengineering (2026) | TGRS Research Map | TGRS