Development and Exploratory Pilot Evaluation of a Dual-Dimensional Shade Matching Training System

OBJECTIVES: Despite the growing aesthetic emphasis in dentistry, a significant gap persists in clinical shade matching training and standardised evaluation. To address this, we developed the Dual-Dimensional Shade Matching Training and Scoring (DDSMTS) system, which aims to enhance practical proficiency and provide an objective scoring framework. METHODS: The DDSMTS system comprised a biomimetic head model with standardised prosthetic/abutment models and shade guides to simulate clinical scenarios, alongside a software system integrating modules for colour difference calculation, random question selection and automatic scoring. The scoring system was established by quantifying colour differences using CIE-LAB values, with scores derived from the ratio of the measured colour difference to the maximum colour difference. To conduct the exploratory pilot evaluation of DDSMTS system, 33 dental students participated in the training and assessment. Their prosthetic and abutment shade matching scores, along with the total score, were recorded at baseline, 1 week and 2 weeks post-training. Statistical analysis was performed using the Friedman test, followed by Dunn's multiple comparisons. RESULTS: A training-dependent improvement in shade matching performance was detected. Scores for prosthetic and abutment matching escalated significantly from baseline (38.28 ± 4.78 and 40.88 ± 2.13, respectively) to 1-week (42.74 ± 3.28 and 45.10 ± 1.38) and 2-week post-training (48.06 ± 1.67 and 48.45 ± 0.97), with all post-training points showing statistical significance (P < .05). CONCLUSION: By enhancing shade matching proficiency, the DDSMTS system could demonstrate promising short-term educational utility in simulated shade matching training in the present study. CLINICAL RELEVANCE: The DDSMTS system provided standardised, reproducible simulated clinical procedures and objective quantitative scoring. Its training could improve shade matching accuracy for the prosthesis and abutment, which can be incorporated into preclinical curricula to boost practical shade discrimination skills.

Authors

Institutions

Publication Details

Journal
International Dental Journal
Published
2026-07-27
DOI
https://doi.org/10.1016/j.identj.2026.109778
Primary Topic
Dental Research and COVID-19
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Exploratory Pilot Evaluation of a Dual-Dimensional Shade Matching Training System

Wenguang Qin, J F Zhang, Huhe Bao, L Zhang et al.
International Dental Journal
Dental Research and COVID-19
article

Development and Exploratory Pilot Evaluation of a Dual-Dimensional Shade Matching Training System

Wenguang Qin, J F Zhang, Huhe Bao, L Zhang, Wen Yang, Guo J, Yi-Xiang Wang, X Y Jiang, T Yang, Birou Zheng
article en

Abstract

OBJECTIVES: Despite the growing aesthetic emphasis in dentistry, a significant gap persists in clinical shade matching training and standardised evaluation. To address this, we developed the Dual-Dimensional Shade Matching Training and Scoring (DDSMTS) system, which aims to enhance practical proficiency and provide an objective scoring framework. METHODS: The DDSMTS system comprised a biomimetic head model with standardised prosthetic/abutment models and shade guides to simulate clinical scenarios, alongside a software system integrating modules for colour difference calculation, random question selection and automatic scoring. The scoring system was established by quantifying colour differences using CIE-LAB values, with scores derived from the ratio of the measured colour difference to the maximum colour difference. To conduct the exploratory pilot evaluation of DDSMTS system, 33 dental students participated in the training and assessment. Their prosthetic and abutment shade matching scores, along with the total score, were recorded at baseline, 1 week and 2 weeks post-training. Statistical analysis was performed using the Friedman test, followed by Dunn's multiple comparisons. RESULTS: A training-dependent improvement in shade matching performance was detected. Scores for prosthetic and abutment matching escalated significantly from baseline (38.28 ± 4.78 and 40.88 ± 2.13, respectively) to 1-week (42.74 ± 3.28 and 45.10 ± 1.38) and 2-week post-training (48.06 ± 1.67 and 48.45 ± 0.97), with all post-training points showing statistical significance (P < .05). CONCLUSION: By enhancing shade matching proficiency, the DDSMTS system could demonstrate promising short-term educational utility in simulated shade matching training in the present study. CLINICAL RELEVANCE: The DDSMTS system provided standardised, reproducible simulated clinical procedures and objective quantitative scoring. Its training could improve shade matching accuracy for the prosthesis and abutment, which can be incorporated into preclinical curricula to boost practical shade discrimination skills.

International Dental JournalVol. 76(5)
Sun Yat-sen University (CN), Stomatology Hospital (CN), Inner Mongolia University of Technology (CN), Guangzhou Medical University (CN)
National Natural Science Foundation of China
Reduced inequalities
Openalex Percentile: Top 5%
Dental Research and COVID-19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.