Suture Configurations With Greater Tendon Purchase Show Increased Time‐Zero Fixation Strength in Endoscopic Proximal Hamstring Repair
PURPOSE: To compare the biomechanical performance of 4 common suture configurations, simple suture, horizontal mattress, Krackow, and modified Mason-Allen, in endoscopic repair of proximal hamstring tendon avulsions. METHODS: Twenty-four cadaveric proximal hamstring tendons were randomized to 1 of the 4 repair groups (simple, horizontal mattress, Krackow, and Mason-Allen; n = 6 each). All constructs underwent uniaxial load-to-failure testing after preconditioning using a mechanical testing system. Primary outcomes included ultimate failure load (N) and linear stiffness (N/mm). Failure modes were recorded. RESULTS: Ultimate failure load was higher for Krackow (283.1 ± 67.9 N; 95% confidence interval [CI], 220.3-345.8) compared with simple suture (141.2 ± 44.6 N; 95% CI, 99.9-182.5; P = .002) and for Mason-Allen (282.5 ± 102.8 N; 95% CI, 187.4-377.6) compared with simple suture (P = .013). Horizontal mattress also showed greater failure load than simple suture (239.7 ± 68.9 N; 95% CI, 176.0-303.4; P = .018). CIs for Krackow, Mason-Allen, and horizontal mattress overlapped. Linear stiffness did not differ significantly among configurations (all P > .05). The predominant failure mode was suture pull-through at the tendon-suture interface (75% of specimens). CONCLUSIONS: Suture configurations with greater tendon purchase (Krackow, Mason-Allen) provided nearly double the failure load compared with simple sutures. Horizontal mattress sutures also provided comparable strength to locking patterns, highlighting a technically feasible alternative when portal access limits locking configurations in endoscopic repair. CLINICAL RELEVANCE: These biomechanical findings suggest that locking configurations, when achievable endoscopically, may enhance repair strength and reduce vulnerability to failure. The comparable performance of the horizontal mattress highlights a practical option when traditional locking patterns are not technically feasible. As endoscopic hamstring repair continues to evolve, optimizing suture configuration represents a key opportunity to improve repair robustness.
Authors
- Madeline M. Blankenship (ORCID: https://orcid.org/0000-0003-0750-5469)
- Justin F.M. Hollenbeck (ORCID: https://orcid.org/0000-0003-1682-0444)
- Tyler D. Perleberg (ORCID: https://orcid.org/0000-0002-1002-6314)
- Marc J. Philippon (ORCID: https://orcid.org/0000-0002-0358-3331)
- Joseph T. Featherall (ORCID: https://orcid.org/0000-0002-2634-9484)
- Onur Hapa (ORCID: https://orcid.org/0000-0001-8154-658X)
- Taylor Calibo (ORCID: https://orcid.org/0000-0001-6046-7356)
- Abigail Zadorozny
- Jonathan A. Godin
Institutions
- Steadman Clinic (US)
- Steadman Philippon Research Institute (US)
Publication Details
- Journal
- Arthroscopy The Journal of Arthroscopic and Related Surgery
- Published
- 2026-07-27
- DOI
- https://doi.org/10.1002/arj.70437
- Primary Topic
- Sports injuries and prevention
- Type
- article
- Field-Weighted Citation Impact