Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord <scp>MRI</scp> at <scp>7T</scp>

ABSTRACT Purpose The design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra‐High‐Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4 × 2‐loop array. Methods The conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out‐of‐phase to actively suppress these lateral side‐lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental maps. Results Human voxel model simulations demonstrated that the passive dipoles improve the transmit field distribution and predicted a 35% gain in SAR efficiency in the spinal cord region. Correspondingly, phantom experiments showed a 25% gain in transmit efficiency and 15% gain in homogeneity in a selected region of interest compared to the loop‐array‐only reference. Conclusion Incorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and efficiency in the thoracic spinal cord region. While homogeneous phantom results offer proof of concept, numerical simulations suggest reliable performance in realistic spine anatomy as well as substantial SAR reduction.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-07-26
DOI
https://doi.org/10.1002/mrm.70517
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T

Marc Dubois, Amira Trabelsi, Aurélien Destruel, Hugo Amat et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

Enhanced Transmit Efficiency of a Loop Array Combined With Out‐of‐Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T

Marc Dubois, Amira Trabelsi, Aurélien Destruel, Hugo Amat, Virginie Callot, David Bendahan, Redha Abdeddaïm, Djamel Berrahou, Sajad Hosseinnezhadian, Stéfan Enoch, Charles Betemps
article en

Abstract

ABSTRACT Purpose The design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra‐High‐Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4 × 2‐loop array. Methods The conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out‐of‐phase to actively suppress these lateral side‐lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental maps. Results Human voxel model simulations demonstrated that the passive dipoles improve the transmit field distribution and predicted a 35% gain in SAR efficiency in the spinal cord region. Correspondingly, phantom experiments showed a 25% gain in transmit efficiency and 15% gain in homogeneity in a selected region of interest compared to the loop‐array‐only reference. Conclusion Incorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and efficiency in the thoracic spinal cord region. While homogeneous phantom results offer proof of concept, numerical simulations suggest reliable performance in realistic spine anatomy as well as substantial SAR reduction.

Magnetic Resonance in Medicine
Centre National de la Recherche Scientifique (FR), DBV Technologies (France) (FR), Aix-Marseille Université (FR), Centre de Résonance Magnétique Biologique et Médicale (FR), Centrale Méditerranée (FR), Hôpital de la Timone (FR)
Openalex Percentile: Top 9%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.