Transabdominal ultrasonography for small-bowel lesions in Crohn’s disease: a prospective comparison with balloon-assisted enteroscopy

Background/Aims: Transabdominal ultrasonography (TUS) is increasingly used to assess small-bowel lesions in Crohn's disease (CD); however, the diagnostic performance of prospective segment-specific data relative to balloon-assisted enteroscopy (BAE) remains limited. Methods: In this prospective, single-center study, 94 patients with CD underwent TUS the day before BAE. The diagnostic accuracy of TUS for mucosal inflammation and stenosis was evaluated separately for the terminal ileum and proximal small bowel, using BAE as the reference standard and endoscopic criteria based on the Simple Endoscopic Score for Crohn's Disease. We performed exploratory analyses of clinical factors associated with TUS detectability, including multivariable logistic regression for inflammatory lesions and exploratory comparisons for stenosis. Results: For mucosal inflammation, TUS sensitivity and specificity were 69% and 94% in the terminal ileum (accuracy, 90%) and 91% and 82% in the proximal small bowel (accuracy, 84%), respectively. For stenosis, the sensitivity and specificity were 78% and 98% in the terminal ileum (accuracy, 96%) and 63% and 89% in the proximal small bowel (accuracy, 84%), respectively. In exploratory analyses of BAEconfirmed inflammatory lesions, anastomotic involvement, history of bowel resection, and small-bowel resection were associated with TUS detectability in univariate analyses. No independent predictors were identified in the multivariable logistic regression. Conclusions: Compared to BAE as the reference standard, TUS showed high specificity and segment-dependent sensitivity for detecting small-bowel inflammation and stenosis. These findings support TUS as a complementary, practiceinforming, and noninvasive assessment tool, indicating that additional evaluation may be needed when clinical suspicion persists despite negative or equivocal TUS findings.

Authors

Institutions

Publication Details

Journal
Intestinal Research
Published
2026-07-27
DOI
https://doi.org/10.5217/ir.2026.00015
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transabdominal ultrasonography for small-bowel lesions in Crohn’s disease: a prospective comparison with balloon-assisted enteroscopy

T. Inokuchi, Sakiko Hiraoka, Junki Toyosawa, Kensuke Takei et al.
Intestinal Research
Gastrointestinal Bleeding Diagnosis and Treatment
article

Transabdominal ultrasonography for small-bowel lesions in Crohn’s disease: a prospective comparison with balloon-assisted enteroscopy

T. Inokuchi, Sakiko Hiraoka, Junki Toyosawa, Kensuke Takei, Yutaka Aoyama, Masahiro Takahara, Keiko Takeuchi, M Ishiguro, Motoyuki Otsuka, Hideki Onishi, Hideaki Kinugasa, Yasushi Yamasaki, Shoko Igawa
article en

Abstract

Background/Aims: Transabdominal ultrasonography (TUS) is increasingly used to assess small-bowel lesions in Crohn's disease (CD); however, the diagnostic performance of prospective segment-specific data relative to balloon-assisted enteroscopy (BAE) remains limited. Methods: In this prospective, single-center study, 94 patients with CD underwent TUS the day before BAE. The diagnostic accuracy of TUS for mucosal inflammation and stenosis was evaluated separately for the terminal ileum and proximal small bowel, using BAE as the reference standard and endoscopic criteria based on the Simple Endoscopic Score for Crohn's Disease. We performed exploratory analyses of clinical factors associated with TUS detectability, including multivariable logistic regression for inflammatory lesions and exploratory comparisons for stenosis. Results: For mucosal inflammation, TUS sensitivity and specificity were 69% and 94% in the terminal ileum (accuracy, 90%) and 91% and 82% in the proximal small bowel (accuracy, 84%), respectively. For stenosis, the sensitivity and specificity were 78% and 98% in the terminal ileum (accuracy, 96%) and 63% and 89% in the proximal small bowel (accuracy, 84%), respectively. In exploratory analyses of BAEconfirmed inflammatory lesions, anastomotic involvement, history of bowel resection, and small-bowel resection were associated with TUS detectability in univariate analyses. No independent predictors were identified in the multivariable logistic regression. Conclusions: Compared to BAE as the reference standard, TUS showed high specificity and segment-dependent sensitivity for detecting small-bowel inflammation and stenosis. These findings support TUS as a complementary, practiceinforming, and noninvasive assessment tool, indicating that additional evaluation may be needed when clinical suspicion persists despite negative or equivocal TUS findings.

Intestinal Research
Okayama University (JP)
Zero hunger
Openalex Percentile: Top 8%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.