Body surface potential driven personalisation of electrophysiological digital twins in hypertrophic cardiomyopathy
BACKGROUND: Hypertrophic cardiomyopathy (HCM) is associated with marked inter-patient heterogeneity in ventricular electrophysiology, contributing to arrhythmic risk that is insufficiently captured by current clinical methods. Electrocardiographic imaging (ECGI) provides high-density body surface potential (BSP) measurements but remains largely descriptive. Computational modelling offers a mechanistic framework to interpret BSP signals in terms of underlying tissue-level properties. METHODS AND FINDINGS: We developed a BSP-driven workflow to construct patient-specific electrophysiology (EP) models of HCM by integrating multimodal clinical imaging with Bayesian model calibration. Anatomically detailed torso-heart finite-element models were generated for 17 HCM patients using thoracic computed tomography (CT), cardiac magnetic resonance imaging (CMR), and 252-electrode BSP recordings. Ventricular depolarisation and repolarisation were simulated using a reaction-eikonal (RE) formulation coupled to a biophysically detailed ToR-ORd-dynCl ionic model. Emulator-based Bayesian history matching (HM) was used to personalise EP parameters, with staged calibration of QRS and T-wave morphology informed by targeted sensitivity analysis. The calibrated cohort reproduced clinical BSP morphology with Pearson correlation coefficient (PCC) [Formula: see text] for a median of 94.0% (IQR: 91.6 to 96.8%) of electrodes, achieving a median PCC of 0.89 (IQR: 0.80 to 0.94) across the full 252-electrode vest. Calibration substantially reduced uncertainty in the high-dimensional EP parameter space while yielding physiologically plausible conduction and repolarisation properties. Models calibrated exclusively to sinus rhythm robustly generalised to right-ventricular (RV) apical pacing without parameter retuning, reproducing clinically observed pacing-induced trends in depolarisation and repolarisation. Exploratory analysis revealed biologically consistent associations between inferred EP parameters and patient demographics. CONCLUSIONS: This study demonstrates that high-density BSP data can be used to functionally personalise mechanistic EP in HCM. The framework captures intrinsic patient-specific EP properties and generalises beyond the calibration condition, supporting its use for mechanistic investigation of arrhythmogenic substrate.
Authors
- Ji‐Jian Chow (ORCID: https://orcid.org/0000-0003-2454-7644)
- Rahul Ghelani
- A. Varnava
- Jagdeep Singh Mohal
- Shambhavi Malik
- Abdul Qayyum
- Prapa Kanagaratnam
- Ludovica Cicci
- Zachary I. Whinnett
- Steven A. Niederer
- Gernot Plank
Institutions
- Imperial College Healthcare NHS Trust (GB)
- Medical University of Graz (AT)
- The Alan Turing Institute (GB)
- Imperial College London (GB)
Publication Details
- Journal
- PLoS Computational Biology
- Published
- 2026-07-27
- DOI
- https://doi.org/10.1371/journal.pcbi.1014555
- Primary Topic
- Cardiac electrophysiology and arrhythmias
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Alan Turing Institute
- British Heart Foundation
- Austrian Science Fund
- National Institutes of Health
- Engineering and Physical Sciences Research Council
- European Research Council