Mockup Test of UHPFRC Prestressed Arch

A two-hinged arch is part of a traditional structural element that can last for thousands of years. This mockup experiment tested two prestressed UHPFRC (Ultra-High-Performance Fibre-Reinforced Concrete) arches with a span of 10.32 m up to failure. Each arch was composed of two semi-arches, which were joined and slightly prestressed to ensure watertightness in the joint. The load acted on one third of the span, inducing eigenshape-like displacements. The first tensile crack appeared under the load at 60 kN, followed by shear cracks and tensile failure in an approximately opposite cross-section. The maximum load reached 170 kN with brittle failure afterwards. The behavior was successfully validated using a 3D finite element analysis and damage-plasticity material model. The mockup experiment proved that upscaling to a real ecoduct arch becomes possible, creating a unique structure with a very long service life.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-07-27
DOI
https://doi.org/10.3390/ma19153193
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mockup Test of UHPFRC Prestressed Arch

Jan Valentin, Pavel Horák, Šárka Pešková, Michal Mára et al.
Materials
Innovative concrete reinforcement materials
article

Mockup Test of UHPFRC Prestressed Arch

Jan Valentin, Pavel Horák, Šárka Pešková, Michal Mára, Petr Konvalinka, Marcel Jogl, Jiří Litoš, Petr Vítek, Martin Válek, Eva Horáková
article en

Abstract

A two-hinged arch is part of a traditional structural element that can last for thousands of years. This mockup experiment tested two prestressed UHPFRC (Ultra-High-Performance Fibre-Reinforced Concrete) arches with a span of 10.32 m up to failure. Each arch was composed of two semi-arches, which were joined and slightly prestressed to ensure watertightness in the joint. The load acted on one third of the span, inducing eigenshape-like displacements. The first tensile crack appeared under the load at 60 kN, followed by shear cracks and tensile failure in an approximately opposite cross-section. The maximum load reached 170 kN with brittle failure afterwards. The behavior was successfully validated using a 3D finite element analysis and damage-plasticity material model. The mockup experiment proved that upscaling to a real ecoduct arch becomes possible, creating a unique structure with a very long service life.

MaterialsVol. 19(15)
Czech Technical University in Prague (CZ), Hochtief (Czechia) (CZ)
Sustainable cities and communities
Openalex Percentile: Top 14%
Innovative concrete reinforcement materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mockup Test of UHPFRC Prestressed Arch — Jan Valentin, Pavel Horák, et al. · Materials (2026) | TGRS Research Map | TGRS