Research on Active Damper Siting Strategy Based on Resonance Modal Analysis

In multi-inverter parallel grid-connected systems, harmonic resonance can lead to performance degradation and even instability. Although installing active dampers (ADs) is considered an effective approach to suppress harmonic resonance, research on the optimal installation positions for ADs is still limited, and specific optimization methods require further exploration. This paper proposes an AD siting strategy based on resonance modal analysis (RMA) and node participation factor (PF) calculations. The method aims to select the installation positions for AD by identifying the nodes that significantly contribute to harmonic resonance, and the validity of this approach is confirmed through modal sensitivity analysis. To address the challenge of conducting RMA with inverter black-box models, impedance models of the inverters are obtained through frequency scanning, and the nodal admittance matrix of the system is established. Additionally, this method considers the impact of changes in grid impedance on AD siting results. Finally, both simulation and experimental results validate the effectiveness of the proposed strategy.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-07-26
DOI
https://doi.org/10.3390/en19153515
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Active Damper Siting Strategy Based on Resonance Modal Analysis

Yalei Yuan, Xiaobin Mu, Xiaokui Sang, Yongxin Zhang et al.
Energies
Microgrid Control and Optimization
article

Research on Active Damper Siting Strategy Based on Resonance Modal Analysis

Yalei Yuan, Xiaobin Mu, Xiaokui Sang, Yongxin Zhang, Muzi Sun
article en

Abstract

In multi-inverter parallel grid-connected systems, harmonic resonance can lead to performance degradation and even instability. Although installing active dampers (ADs) is considered an effective approach to suppress harmonic resonance, research on the optimal installation positions for ADs is still limited, and specific optimization methods require further exploration. This paper proposes an AD siting strategy based on resonance modal analysis (RMA) and node participation factor (PF) calculations. The method aims to select the installation positions for AD by identifying the nodes that significantly contribute to harmonic resonance, and the validity of this approach is confirmed through modal sensitivity analysis. To address the challenge of conducting RMA with inverter black-box models, impedance models of the inverters are obtained through frequency scanning, and the nodal admittance matrix of the system is established. Additionally, this method considers the impact of changes in grid impedance on AD siting results. Finally, both simulation and experimental results validate the effectiveness of the proposed strategy.

EnergiesVol. 19(15)
North China Electric Power University (CN), Hefei University of Technology (CN), State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 11%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Active Damper Siting Strategy Based on Resonance Modal Analysis — Yalei Yuan, Xiaobin Mu, et al. · Energies (2026) | TGRS Research Map | TGRS