FF-fusion: A knowledge-distilled lightweight visible–infrared image fusion framework for Forest fire monitoring

Visible–infrared image fusion offers an effective strategy for forest fire monitoring by integrating complementary information from visible-light and thermal-infrared modalities, particularly under smoke interference, low illumination, and complex forest backgrounds. However, forest-fire-specific paired datasets remain scarce, and lightweight fusion methods have seldom been evaluated under real-world monitoring scenarios and edge-deployment constraints. To address these limitations, this study constructs TF-1770, a spatially aligned visible–infrared forest fire dataset collected from ground-based and UAV-based firefighting scenes. The dataset comprises paired visible-light and thermal-infrared images captured under diverse viewpoints, smoke densities, illumination conditions, and target scales. Based on TF-1770, we propose FF-Fusion, a lightweight visible–infrared image fusion framework based on knowledge distillation. The teacher network learns robust multimodal representations through wavelet-based fusion and cross-modal feature modeling, while the student network incorporates re-parameterizable convolution blocks to enable efficient edge inference. Experimental results on TF-1770 show that FF-Fusion achieves entropy, standard deviation, average gradient, visual information fidelity, and edge information transfer metric values of 7.10, 43.66, 10.83, 0.649, and 0.584, respectively. The deployable student model maintains a compact size of only 1.34 MB. Downstream detection experiments demonstrate that the fused images enhance the perception of flames, smoke, and firefighters. Moreover, edge-deployment tests on heterogeneous platforms verify the feasibility of FF-Fusion for resource-constrained devices. These results indicate that lightweight visible–infrared image fusion can provide effective visual support for practical forest fire monitoring. The proposed workflow, spanning dataset construction, model design, downstream validation, and edge deployment, may also serve as a reference for future deployable ecological monitoring systems.

Authors

Institutions

Publication Details

Journal
Ecological Informatics
Published
2026-07-26
DOI
https://doi.org/10.1016/j.ecoinf.2026.103952
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FF-fusion: A knowledge-distilled lightweight visible–infrared image fusion framework for Forest fire monitoring

Long Qi, Wuyang Hu, XC Wu, Ying Wang et al.
Ecological Informatics
Fire Detection and Safety Systems
article

FF-fusion: A knowledge-distilled lightweight visible–infrared image fusion framework for Forest fire monitoring

Long Qi, Wuyang Hu, XC Wu, Ying Wang, Zhi Jiang, Gui Zhang, Zhuo Ouyang, Wenping Liu, Qian Yu
article en

Abstract

Visible–infrared image fusion offers an effective strategy for forest fire monitoring by integrating complementary information from visible-light and thermal-infrared modalities, particularly under smoke interference, low illumination, and complex forest backgrounds. However, forest-fire-specific paired datasets remain scarce, and lightweight fusion methods have seldom been evaluated under real-world monitoring scenarios and edge-deployment constraints. To address these limitations, this study constructs TF-1770, a spatially aligned visible–infrared forest fire dataset collected from ground-based and UAV-based firefighting scenes. The dataset comprises paired visible-light and thermal-infrared images captured under diverse viewpoints, smoke densities, illumination conditions, and target scales. Based on TF-1770, we propose FF-Fusion, a lightweight visible–infrared image fusion framework based on knowledge distillation. The teacher network learns robust multimodal representations through wavelet-based fusion and cross-modal feature modeling, while the student network incorporates re-parameterizable convolution blocks to enable efficient edge inference. Experimental results on TF-1770 show that FF-Fusion achieves entropy, standard deviation, average gradient, visual information fidelity, and edge information transfer metric values of 7.10, 43.66, 10.83, 0.649, and 0.584, respectively. The deployable student model maintains a compact size of only 1.34 MB. Downstream detection experiments demonstrate that the fused images enhance the perception of flames, smoke, and firefighters. Moreover, edge-deployment tests on heterogeneous platforms verify the feasibility of FF-Fusion for resource-constrained devices. These results indicate that lightweight visible–infrared image fusion can provide effective visual support for practical forest fire monitoring. The proposed workflow, spanning dataset construction, model design, downstream validation, and edge deployment, may also serve as a reference for future deployable ecological monitoring systems.

Ecological InformaticsVol. 97
Central South University of Forestry and Technology (CN), Central South University (CN), Hunan Vocational Institute of Technology (CN), Hunan University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Hunan Province
Openalex Percentile: Top 9%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.