In Vivo Measurement of Taurine With Optimized Double‐Quantum Filtering Magnetic Resonance Spectroscopy

PURPOSE: To enhance the accuracy and reproducibility for in vivo taurine quantification using the double-quantum filtering (DQF) technique. METHODS: Simulations and phantom experiments were conducted at both 7 T and 3 T to determine the optimal parameter τ by calculating the taurine purity index among other neighboring metabolites. The frequency-selective read-pulse bandwidth and the dephasing/rephasing gradient moments were further adjusted to reduce residual water side band interference. Rat models of C6 gliomas were compared to normal brain for taurine level at 7 T. Metabolomics was conducted to validate the accuracy of taurine quantification. Human gray and white matter taurine differences were revealed at 3 T. Test-retest reliability was evaluated on humans. RESULTS: Simulations and phantom experiments identified optimal τ for maximizing taurine signal purity as 102 ms at 7 T and 92 ms at 3 T. The best combinations of parameters for minimal water interference were determined at 3 T. Optimized DQF sequences yielded lower CRLBs. In rat brains, taurine concentration measured with optimized DQF sequences exhibited strong correlation with metabolomics, outperforming both conventional MRS and nonoptimized DQF sequences. Only the optimized method revealed significant taurine concentration differences between gray and white matter. Test-retest demonstrated good reproducibility in gray matter (ICC = 0.82) for the optimized method. CONCLUSION: The optimized DQF method enhances taurine detection accuracy and robustness in both animal and human studies and was for the first time applied in human brain taurine test at 3 T.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-07-26
DOI
https://doi.org/10.1002/mrm.70511
Primary Topic
Aldose Reductase and Taurine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Measurement of Taurine With Optimized Double‐Quantum Filtering Magnetic Resonance Spectroscopy

M C Wang, Ye‐Feng Yao, Dingyi Lin, Haitao Zhang et al.
Magnetic Resonance in Medicine
Aldose Reductase and Taurine
article

In Vivo Measurement of Taurine With Optimized Double‐Quantum Filtering Magnetic Resonance Spectroscopy

M C Wang, Ye‐Feng Yao, Dingyi Lin, Haitao Zhang, Yang Cao, Chenting Ye, Yufan Zhou, Jiaqiang Zhou
article en

Abstract

PURPOSE: To enhance the accuracy and reproducibility for in vivo taurine quantification using the double-quantum filtering (DQF) technique. METHODS: Simulations and phantom experiments were conducted at both 7 T and 3 T to determine the optimal parameter τ by calculating the taurine purity index among other neighboring metabolites. The frequency-selective read-pulse bandwidth and the dephasing/rephasing gradient moments were further adjusted to reduce residual water side band interference. Rat models of C6 gliomas were compared to normal brain for taurine level at 7 T. Metabolomics was conducted to validate the accuracy of taurine quantification. Human gray and white matter taurine differences were revealed at 3 T. Test-retest reliability was evaluated on humans. RESULTS: Simulations and phantom experiments identified optimal τ for maximizing taurine signal purity as 102 ms at 7 T and 92 ms at 3 T. The best combinations of parameters for minimal water interference were determined at 3 T. Optimized DQF sequences yielded lower CRLBs. In rat brains, taurine concentration measured with optimized DQF sequences exhibited strong correlation with metabolomics, outperforming both conventional MRS and nonoptimized DQF sequences. Only the optimized method revealed significant taurine concentration differences between gray and white matter. Test-retest demonstrated good reproducibility in gray matter (ICC = 0.82) for the optimized method. CONCLUSION: The optimized DQF method enhances taurine detection accuracy and robustness in both animal and human studies and was for the first time applied in human brain taurine test at 3 T.

Magnetic Resonance in Medicine
Ministry of Education (NZ), Sir Run Run Shaw Hospital (CN), Second Affiliated Hospital of Zhejiang University (CN), East China Normal University (CN)
Clean water and sanitation
Openalex Percentile: Top 12%
Aldose Reductase and Taurine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.