High pressure transcranial focused ultrasound stimulation induces parameter-dependent cell-type specific effects

Transcranial focused ultrasound (tFUS) is a promising technique that has been shown to have high spatial precision, deep brain penetration, and cell-type specificity. Intracranial electrophysiological recordings can measure neural responses to tFUS with high spatial and temporal resolution, but conventional silicon-based multi-electrode arrays cause vibration artifacts induced by increased tFUS pressure. In this study, using an ultraflexible nanoelectric thread electrode, we demonstrate the cell-type selective effects of tFUS under high acoustic pressure with a broad range of ultrasound parameters. We observe that their flexibility mitigates vibrations, eliminating artifacts even at high pressure levels. We observed a positive nonlinear relationship between pressure levels and both time-locked and delayed spiking responses in multiple cell types. We show that higher pressure levels produce distinct response curves across independently varied ultrasound pulse repetition frequency and duty cycle, suggesting the need for further investigation of pressure effects.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2026-07-27
DOI
https://doi.org/10.1038/s41378-026-01391-1
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High pressure transcranial focused ultrasound stimulation induces parameter-dependent cell-type specific effects

Sandhya Ramachandran, Chong Xie, Bin He, Katherine Bray et al.
Microsystems & Nanoengineering
Ultrasound and Hyperthermia Applications
article

High pressure transcranial focused ultrasound stimulation induces parameter-dependent cell-type specific effects

Sandhya Ramachandran, Chong Xie, Bin He, Katherine Bray, Chih-Yu Yeh, Pavlo Zolotavin, Huan Gao, Kai Yu, Keunhyung Lee, Siyi Wang, Lan Luan
article en

Abstract

Transcranial focused ultrasound (tFUS) is a promising technique that has been shown to have high spatial precision, deep brain penetration, and cell-type specificity. Intracranial electrophysiological recordings can measure neural responses to tFUS with high spatial and temporal resolution, but conventional silicon-based multi-electrode arrays cause vibration artifacts induced by increased tFUS pressure. In this study, using an ultraflexible nanoelectric thread electrode, we demonstrate the cell-type selective effects of tFUS under high acoustic pressure with a broad range of ultrasound parameters. We observe that their flexibility mitigates vibrations, eliminating artifacts even at high pressure levels. We observed a positive nonlinear relationship between pressure levels and both time-locked and delayed spiking responses in multiple cell types. We show that higher pressure levels produce distinct response curves across independently varied ultrasound pulse repetition frequency and duty cycle, suggesting the need for further investigation of pressure effects.

Microsystems & NanoengineeringVol. 12(1)
University of Connecticut (US), Rice University (US), Carnegie Mellon University (US)
National Institutes of Health, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 17%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.