Normal CURE and RURE values for displacement encoding with stimulated echoes (DENSE) at 1.5 Tesla MRI

Abstract Assessment of left ventricular (LV) dyssynchrony is important for diagnosing and guiding therapy in heart failure. Displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) quantifies myocardial dyssynchrony but lacks robust reference values. Forty healthy Caucasian volunteers (18–60 years) with no history of cardiac diseases underwent CMR at 1.5T MRI scanner using 2D spiral cine DENSE research sequence. Three short-axis slices (basal, mid-ventricular, apical) were acquired from the LV. Phase images were processed with open-source DENSEanalysis software to measure circumferential (E cc ) and radial (E rr ) strains, from which circumferential uniformity estimate (CURE) and radial uniformity estimate (RURE) were computed. Participants were categorized by sex and age into groups (18–30, 31–41, and 42–60 years). DENSE-derived strain values were also compared to those obtained using MRI feature tracking (FT). Males and females differed in average E cc (− 18 ± 4 vs. − 19 ± 5%, p = 0.01) and E rr (44 ± 20 vs. 36 ± 22%, p = 0.001), with no differences due to age. The apical segment of RURE was higher in males ( p = 0.04), and age did not affect RURE. CURE showed no sex‑ or age‑related variation. The lower limit of normal was 0.80 for CURE and 0.64 for RURE. When FT was compared to DENSE, mean E cc was similar (− 20% vs. − 19%), though patient-level agreement was moderate (Intra class correlation (ICC) = 0.588, p = 0.013); FT showed lower E rr (mean 34% vs. 42%; ICC 0.304, p = 0.062). CURE demonstrated stable values across age and sex in healthy volunteers, supporting its use as a robust marker of LV dyssynchrony with a normal threshold of ≥ 0.80. In contrast, RURE showed greater variability, although a lower reference limit of ≥ 0.64 was established.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-07-27
DOI
https://doi.org/10.1038/s41598-026-63200-z
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normal CURE and RURE values for displacement encoding with stimulated echoes (DENSE) at 1.5 Tesla MRI

Saara Sillanmäki, Minna Husso, Xiaoying Cai, Martin Ugander et al.
Scientific Reports
Cardiac Imaging and Diagnostics
article

Normal CURE and RURE values for displacement encoding with stimulated echoes (DENSE) at 1.5 Tesla MRI

Saara Sillanmäki, Minna Husso, Xiaoying Cai, Martin Ugander, Suvi Hartikainen, M Hedman, Elias Ylä-Herttuala, Mimmi Liukkonen
article en

Abstract

Abstract Assessment of left ventricular (LV) dyssynchrony is important for diagnosing and guiding therapy in heart failure. Displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) quantifies myocardial dyssynchrony but lacks robust reference values. Forty healthy Caucasian volunteers (18–60 years) with no history of cardiac diseases underwent CMR at 1.5T MRI scanner using 2D spiral cine DENSE research sequence. Three short-axis slices (basal, mid-ventricular, apical) were acquired from the LV. Phase images were processed with open-source DENSEanalysis software to measure circumferential (E cc ) and radial (E rr ) strains, from which circumferential uniformity estimate (CURE) and radial uniformity estimate (RURE) were computed. Participants were categorized by sex and age into groups (18–30, 31–41, and 42–60 years). DENSE-derived strain values were also compared to those obtained using MRI feature tracking (FT). Males and females differed in average E cc (− 18 ± 4 vs. − 19 ± 5%, p = 0.01) and E rr (44 ± 20 vs. 36 ± 22%, p = 0.001), with no differences due to age. The apical segment of RURE was higher in males ( p = 0.04), and age did not affect RURE. CURE showed no sex‑ or age‑related variation. The lower limit of normal was 0.80 for CURE and 0.64 for RURE. When FT was compared to DENSE, mean E cc was similar (− 20% vs. − 19%), though patient-level agreement was moderate (Intra class correlation (ICC) = 0.588, p = 0.013); FT showed lower E rr (mean 34% vs. 42%; ICC 0.304, p = 0.062). CURE demonstrated stable values across age and sex in healthy volunteers, supporting its use as a robust marker of LV dyssynchrony with a normal threshold of ≥ 0.80. In contrast, RURE showed greater variability, although a lower reference limit of ≥ 0.64 was established.

Scientific Reports
Karolinska University Hospital (SE), University of Helsinki (FI), University of Eastern Finland (FI), Royal North Shore Hospital (AU), Helsinki University Hospital (FI), Karolinska Institutet (SE), Kuopio University Hospital (FI), Medical Solutions (GB), Hospital District of Helsinki and Uusimaa (FI)
Academy of Finland, Kuopion Yliopistollinen Sairaala, Siemens Healthineers
Good health and well-being
Openalex Percentile: Top 10%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.