RBC-AD: conformal anomaly detection with explicit false-alarm control for the Tennessee Eastman Process

Fault detection in the Tennessee Eastman Process (TEP) is challenged by transient dynamics, post-injection regime transitions, and score drift that destabilize fixed-threshold detectors and increase false alarms. In the proposed Risk-Budgeted Conformal Anomaly Detection (RBC-AD) framework, a calibration-based anomaly detector integrates a causal forecasting backbone, frequency-aware scoring, and conformal decisioning. The forecaster is a dilated temporal convolutional network with causal self-attention, trained on fault-free runs to predict one-step-ahead Gaussian parameters by minimizing negative log-likelihood. Detection then scores each window using a fused nonconformity measure that combines the window-averaged predictive log-likelihood with an FFT-based frequency deviation term, using robust normalization fitted on a held-out calibration split and tuning the fusion weight under leakage-controlled splits. Conformal quantiles at miscoverage level α=0.05 define normal, uncertain, and anomaly states with finite-sample correction. Run-level partitioning over 500 runs per split and post-injection sampling (3,000 normal windows, 8,000 fault windows) achieves ROC-AUC = 1.000 and PR-AUC = 1.000 under the post-injection-only protocol; full-stream results provide the deployment-relevant assessment. Static conformal thresholds (θu=0.1977, θa=0.3033) yield F1 = 0.9989 and F1 = 0.9999. Deployment selects an uncertainty threshold to satisfy an empirical normal alarm-rate target of 0.05. Full-stream evaluation reports uncertainty rate and detection delay under k-consecutive alarm logic, with optional drift-triggered recalibration using normal-stream scores.

Authors

Institutions

Publication Details

Journal
Connection Science
Published
2026-07-26
DOI
https://doi.org/10.1080/09540091.2026.2707826
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RBC-AD: conformal anomaly detection with explicit false-alarm control for the Tennessee Eastman Process

Kamran Ahmad Awan, Mana Saleh Al Reshan, Asadullah Shaikh, Hamad Almansour et al.
Connection Science
Fault Detection and Control Systems
article

RBC-AD: conformal anomaly detection with explicit false-alarm control for the Tennessee Eastman Process

Kamran Ahmad Awan, Mana Saleh Al Reshan, Asadullah Shaikh, Hamad Almansour, Yousef Asiri, Muhammad Mudasir, Iqra Ameer
article en

Abstract

Fault detection in the Tennessee Eastman Process (TEP) is challenged by transient dynamics, post-injection regime transitions, and score drift that destabilize fixed-threshold detectors and increase false alarms. In the proposed Risk-Budgeted Conformal Anomaly Detection (RBC-AD) framework, a calibration-based anomaly detector integrates a causal forecasting backbone, frequency-aware scoring, and conformal decisioning. The forecaster is a dilated temporal convolutional network with causal self-attention, trained on fault-free runs to predict one-step-ahead Gaussian parameters by minimizing negative log-likelihood. Detection then scores each window using a fused nonconformity measure that combines the window-averaged predictive log-likelihood with an FFT-based frequency deviation term, using robust normalization fitted on a held-out calibration split and tuning the fusion weight under leakage-controlled splits. Conformal quantiles at miscoverage level α=0.05 define normal, uncertain, and anomaly states with finite-sample correction. Run-level partitioning over 500 runs per split and post-injection sampling (3,000 normal windows, 8,000 fault windows) achieves ROC-AUC = 1.000 and PR-AUC = 1.000 under the post-injection-only protocol; full-stream results provide the deployment-relevant assessment. Static conformal thresholds (θu=0.1977, θa=0.3033) yield F1 = 0.9989 and F1 = 0.9999. Deployment selects an uncertainty threshold to satisfy an empirical normal alarm-rate target of 0.05. Full-stream evaluation reports uncertainty rate and detection delay under k-consecutive alarm logic, with optional drift-triggered recalibration using normal-stream scores.

Connection ScienceVol. 38(1)
Pennsylvania State University (US), University of Haripur (PK), Numerical Method (China) (CN), Najran University (SA)
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.