Research on Transient and Steady‐State Coordinated Control Strategy for Two‐Stage DC/DC Converter

ABSTRACT This paper focuses on the 270 V/28 V DC power distribution architecture for more electric aircraft, aiming to resolve the inherent trade‐off between steady‐state efficiency and dynamic response in conventional two‐stage DC/DC converters. A bidirectional converter based on the Buck–Boost + LLC topology and its coordinated control strategy are investigated. The proposed scheme integrates both steady‐state and transient control. In steady‐state operation, the Buck–Boost stage adopts variable‐frequency control to achieve soft switching, whereas the full‐bridge LLC resonant converter operates at a fixed frequency to minimize power loss. During transient conditions, dynamic pulse regulation is implemented based on state‐plane analysis of the full‐bridge LLC resonant converter, enabling fast operating‐point transition along the optimal trajectory and achieving superior coordination between efficiency and dynamic performance. Simulation and experimental results demonstrate that the converter maintains stable output over a wide input range of 230–290 V, with an overall efficiency exceeding 90% and full‐range soft switching for all power switches. Under load step changes, the absolute output voltage deviation is reduced by 113 mV (37.7% reduction) during light‐to‐heavy load transition and by 120 mV (42.9% reduction) during heavy‐to‐light load transition. Relative to the rated 28 V output voltage, the deviations are reduced by 0.41% and 0.43% under the two operating conditions, respectively. In addition, the settling time is shortened by 10 ms (33% performance improvement) in both cases, with smooth and unique transient response trajectories. The proposed solution effectively improves dynamic response at the millisecond level while guaranteeing high efficiency and stable operation.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2026-07-26
DOI
https://doi.org/10.1002/cta.70567
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Transient and Steady‐State Coordinated Control Strategy for Two‐Stage DC/DC Converter

LI Hai-meng, Xi Zhang, Boyuan Wang, Yi Zhang et al.
International Journal of Circuit Theory and Applications
Advanced DC-DC Converters
article

Research on Transient and Steady‐State Coordinated Control Strategy for Two‐Stage DC/DC Converter

LI Hai-meng, Xi Zhang, Boyuan Wang, Yi Zhang, Zhigang Chen, Sheng‐Wen Fan
article en

Abstract

ABSTRACT This paper focuses on the 270 V/28 V DC power distribution architecture for more electric aircraft, aiming to resolve the inherent trade‐off between steady‐state efficiency and dynamic response in conventional two‐stage DC/DC converters. A bidirectional converter based on the Buck–Boost + LLC topology and its coordinated control strategy are investigated. The proposed scheme integrates both steady‐state and transient control. In steady‐state operation, the Buck–Boost stage adopts variable‐frequency control to achieve soft switching, whereas the full‐bridge LLC resonant converter operates at a fixed frequency to minimize power loss. During transient conditions, dynamic pulse regulation is implemented based on state‐plane analysis of the full‐bridge LLC resonant converter, enabling fast operating‐point transition along the optimal trajectory and achieving superior coordination between efficiency and dynamic performance. Simulation and experimental results demonstrate that the converter maintains stable output over a wide input range of 230–290 V, with an overall efficiency exceeding 90% and full‐range soft switching for all power switches. Under load step changes, the absolute output voltage deviation is reduced by 113 mV (37.7% reduction) during light‐to‐heavy load transition and by 120 mV (42.9% reduction) during heavy‐to‐light load transition. Relative to the rated 28 V output voltage, the deviations are reduced by 0.41% and 0.43% under the two operating conditions, respectively. In addition, the settling time is shortened by 10 ms (33% performance improvement) in both cases, with smooth and unique transient response trajectories. The proposed solution effectively improves dynamic response at the millisecond level while guaranteeing high efficiency and stable operation.

International Journal of Circuit Theory and Applications
North China University of Technology (CN), North China Electric Power University (CN), China Academy of Building Research (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 16%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.