Numerical Investigation of Key Parameters Influencing Stone Column Behavior and the Impact of Column Arrangement on Liquefaction Mitigation in Sandy Soils

Abstract One of the most critical challenges faced by geotechnical engineers is soil liquefaction and its associated damage. When saturated soil is subjected to seismic vibrations, its static equilibrium is disrupted due to irregular dynamic forces, leading to the occurrence of liquefaction. This study first validates the numerical model using the results of VELACS physical modeling. Subsequently, a 3D numerical analysis is conducted using FLAC 3D to perform a parametric study on the factors influencing the pore water pressure generation, such as ground acceleration, soil compaction, and stone column dimensions. The results indicate that an increase in the stone column diameter consistently reduces settlement and horizontal displacement. However, this trend diminishes for diameters exceeding 0.8 m. With an increase in peak ground acceleration, soil mass displacement increases in all earthquake scenarios. A nearly linear relationship is observed between acceleration increase and excess pore water pressure at distances of 3.5 and 5 m. On the other hand, higher soil compaction reduces displacement but has a limited effect on decreasing excess pore water pressure within the soil mass. The findings reveal that the effective influence range of stone columns extends up to 1.5 m in all directions, beyond which the impact on liquefaction mitigation is minimal. Therefore, it is recommended to install stone columns at a maximum center-to-center spacing of 3 m. A configuration involving multiple stone columns demonstrated superior performance in dissipating pore water pressure and limiting deformations, especially at larger distances and depths. The results contribute to a more robust understanding of stone column behavior under dynamic loading and offer a practical framework for their effective implementation in earthquake-prone regions.

Authors

Institutions

Publication Details

Journal
Journal of structural design and construction practice.
Published
2026-07-26
DOI
https://doi.org/10.1061/jsdccc.sceng-2084
Primary Topic
Geotechnical Engineering and Soil Stabilization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation of Key Parameters Influencing Stone Column Behavior and the Impact of Column Arrangement on Liquefaction Mitigation in Sandy Soils

Ali Akhtarpour, Javad Tahamtan, Khashayar Khazayi, Morteza Ryan et al.
Journal of structural design and construction practice.
Geotechnical Engineering and Soil Stabilization
article

Numerical Investigation of Key Parameters Influencing Stone Column Behavior and the Impact of Column Arrangement on Liquefaction Mitigation in Sandy Soils

Ali Akhtarpour, Javad Tahamtan, Khashayar Khazayi, Morteza Ryan, Faezeh Ghasemi
article en

Abstract

Abstract One of the most critical challenges faced by geotechnical engineers is soil liquefaction and its associated damage. When saturated soil is subjected to seismic vibrations, its static equilibrium is disrupted due to irregular dynamic forces, leading to the occurrence of liquefaction. This study first validates the numerical model using the results of VELACS physical modeling. Subsequently, a 3D numerical analysis is conducted using FLAC 3D to perform a parametric study on the factors influencing the pore water pressure generation, such as ground acceleration, soil compaction, and stone column dimensions. The results indicate that an increase in the stone column diameter consistently reduces settlement and horizontal displacement. However, this trend diminishes for diameters exceeding 0.8 m. With an increase in peak ground acceleration, soil mass displacement increases in all earthquake scenarios. A nearly linear relationship is observed between acceleration increase and excess pore water pressure at distances of 3.5 and 5 m. On the other hand, higher soil compaction reduces displacement but has a limited effect on decreasing excess pore water pressure within the soil mass. The findings reveal that the effective influence range of stone columns extends up to 1.5 m in all directions, beyond which the impact on liquefaction mitigation is minimal. Therefore, it is recommended to install stone columns at a maximum center-to-center spacing of 3 m. A configuration involving multiple stone columns demonstrated superior performance in dissipating pore water pressure and limiting deformations, especially at larger distances and depths. The results contribute to a more robust understanding of stone column behavior under dynamic loading and offer a practical framework for their effective implementation in earthquake-prone regions.

Journal of structural design and construction practice.Vol. 31(4)
Shahrekord University (IR), Tabaran Institute of Higher Education (IR), Shahroud University of Medical Sciences (IR), Ferdowsi University of Mashhad (IR), Semnan University (IR)
Openalex Percentile: Top 14%
Geotechnical Engineering and Soil Stabilization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.