Performance of the Occlutech® Atrial Flow Regulator Device in Patients With Either Failing Fontan Circulations or Irreversible Pulmonary Hypertension

BACKGROUND: The presence of an atrial level right to left shunt may be desirable in patients with severe pulmonary hypertension (PH) or failing Fontan circulation. The Occlutech Atrial Flow Regulator (AFR) was originally designed to create an atrial shunt for left heart failure and is currently being used off-label in patients with PH or failing Fontan circulation. There is limited evidence supporting AFR use for these indications. AIMS AND METHODS: We performed a retrospective review of consecutive patients with Fontan circulation or severe irreversible PH who underwent AFR implantation. Comprehensive data were collected and analyzed. RESULTS: Sixteen Fontan and eight PH patients underwent AFR implantation. Median age and weight at implantation were 7.5 years (range 2-34) and 22.3 kg (range 11.3-80), respectively. Twenty-eight devices were implanted in 24 patients during 27 procedures. Successful deployment was achieved in all. The device proved versatile and durable across diverse anatomic substrates, even after multiple repositioning attempts. There were no deaths or urgent surgical interventions. Transseptal puncture or Fontan baffle perforation using a Brockenbrough needle or radiofrequency before AFR implantation was required in 10 patients (42%). The most serious complication was a hemorrhagic stroke related to anticoagulation therapy. Thrombotic events occurred in three Fontan patients (11% of all implantations). CONCLUSIONS: AFR appears to be a promising adjunctive option for PH and failing Fontan patients, with acceptable safety and clinically effective results. Device thrombosis remains a risk, particularly with smaller devices in Fontan circulation, likely related to the Fontan patients' underlying hypercoagulable state.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-07-26
DOI
https://doi.org/10.1002/ccd.70776
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the Occlutech® Atrial Flow Regulator Device in Patients With Either Failing Fontan Circulations or Irreversible Pulmonary Hypertension

James Kuo, Gregory A. Fleming, Konstantin Averin, Mark H. Hoyer et al.
Catheterization and Cardiovascular Interventions
Congenital Heart Disease Studies
article

Performance of the Occlutech® Atrial Flow Regulator Device in Patients With Either Failing Fontan Circulations or Irreversible Pulmonary Hypertension

James Kuo, Gregory A. Fleming, Konstantin Averin, Mark H. Hoyer, Jenny E. Zablah, Gareth John Morgan, Mehmet Küçük, Christopher Iskander, Mark A. Law, Ryan Leahy, Oliver Aregullin, Dennis Vanloozen
article en

Abstract

BACKGROUND: The presence of an atrial level right to left shunt may be desirable in patients with severe pulmonary hypertension (PH) or failing Fontan circulation. The Occlutech Atrial Flow Regulator (AFR) was originally designed to create an atrial shunt for left heart failure and is currently being used off-label in patients with PH or failing Fontan circulation. There is limited evidence supporting AFR use for these indications. AIMS AND METHODS: We performed a retrospective review of consecutive patients with Fontan circulation or severe irreversible PH who underwent AFR implantation. Comprehensive data were collected and analyzed. RESULTS: Sixteen Fontan and eight PH patients underwent AFR implantation. Median age and weight at implantation were 7.5 years (range 2-34) and 22.3 kg (range 11.3-80), respectively. Twenty-eight devices were implanted in 24 patients during 27 procedures. Successful deployment was achieved in all. The device proved versatile and durable across diverse anatomic substrates, even after multiple repositioning attempts. There were no deaths or urgent surgical interventions. Transseptal puncture or Fontan baffle perforation using a Brockenbrough needle or radiofrequency before AFR implantation was required in 10 patients (42%). The most serious complication was a hemorrhagic stroke related to anticoagulation therapy. Thrombotic events occurred in three Fontan patients (11% of all implantations). CONCLUSIONS: AFR appears to be a promising adjunctive option for PH and failing Fontan patients, with acceptable safety and clinically effective results. Device thrombosis remains a risk, particularly with smaller devices in Fontan circulation, likely related to the Fontan patients' underlying hypercoagulable state.

Catheterization and Cardiovascular Interventions
Duke University (US), Riley Hospital for Children (US), University of Alabama at Birmingham (US), Cook Children's Medical Center (US), Children's Hospital Colorado (US), Cohen Children's Medical Center (US), Duke Medical Center (US), Helen DeVos Children's Hospital (US), Children's Healthcare of Atlanta (US), Indiana University – Purdue University Indianapolis (US), University of Colorado Denver (US)
Good health and well-being
Openalex Percentile: Top 9%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.