One-year performance and loss analysis of vertical east-west bifacial PV modules benchmarked against tilted configurations

Vertical east–west bifacial photovoltaic systems offer potential advantages, including reduced soiling, land-use compatibility, and morning–afternoon generation profiles. However, their performance under low-latitude coastal climates remains insufficiently documented. This study presents a one-year field assessment of a vertical east–west bifacial PV module installed in Lima, Peru, and compares it with north-facing tilted bifacial and monofacial modules. Current–voltage curves, front- and rear-side irradiances, and module temperatures were monitored at 5 min resolution. DC energy yield and module performance ratio were analyzed using successive corrections for temperature, bifaciality, and single-diode-model-based I–V reconstruction to identify dominant loss mechanisms. The tilted bifacial module achieved the highest annual DC yield, 3.79 kWh/kW/day, exceeding the monofacial module by 6.5%. In contrast, the vertical bifacial module reached 2.82 kWh/kW/day, despite receiving a total incident reference yield comparable to that of the monofacial configuration. Temperature-related losses were similar across modules, approximately 3–5%, and did not explain this gap. Instead, the vertical configuration was mainly limited by bifaciality-related losses of 11.6%, due to the high fraction of incident irradiance on the less efficient rear side, and structural self-shading losses of approximately 4.5% annually. After all corrections, performance ratios converged to 92–93%, indicating comparable intrinsic module behavior. These results provide experimental evidence and a replicable loss-decomposition framework for assessing vertical bifacial PV systems and guiding module design. This framework is particularly relevant where urban integration, reduced maintenance, land-use constraints, or adapted morning–afternoon generation profiles may justify vertical deployment despite lower annual energy yield.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-07-26
DOI
https://doi.org/10.1016/j.solener.2026.114926
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-year performance and loss analysis of vertical east-west bifacial PV modules benchmarked against tilted configurations

José Rubén Angulo Abanto, Jan Amaru Töfflinger, Michael A. García
Solar Energy
Photovoltaic System Optimization Techniques
article

One-year performance and loss analysis of vertical east-west bifacial PV modules benchmarked against tilted configurations

José Rubén Angulo Abanto, Jan Amaru Töfflinger, Michael A. García
article en

Abstract

Vertical east–west bifacial photovoltaic systems offer potential advantages, including reduced soiling, land-use compatibility, and morning–afternoon generation profiles. However, their performance under low-latitude coastal climates remains insufficiently documented. This study presents a one-year field assessment of a vertical east–west bifacial PV module installed in Lima, Peru, and compares it with north-facing tilted bifacial and monofacial modules. Current–voltage curves, front- and rear-side irradiances, and module temperatures were monitored at 5 min resolution. DC energy yield and module performance ratio were analyzed using successive corrections for temperature, bifaciality, and single-diode-model-based I–V reconstruction to identify dominant loss mechanisms. The tilted bifacial module achieved the highest annual DC yield, 3.79 kWh/kW/day, exceeding the monofacial module by 6.5%. In contrast, the vertical bifacial module reached 2.82 kWh/kW/day, despite receiving a total incident reference yield comparable to that of the monofacial configuration. Temperature-related losses were similar across modules, approximately 3–5%, and did not explain this gap. Instead, the vertical configuration was mainly limited by bifaciality-related losses of 11.6%, due to the high fraction of incident irradiance on the less efficient rear side, and structural self-shading losses of approximately 4.5% annually. After all corrections, performance ratios converged to 92–93%, indicating comparable intrinsic module behavior. These results provide experimental evidence and a replicable loss-decomposition framework for assessing vertical bifacial PV systems and guiding module design. This framework is particularly relevant where urban integration, reduced maintenance, land-use constraints, or adapted morning–afternoon generation profiles may justify vertical deployment despite lower annual energy yield.

Solar EnergyVol. 317
Pontificia Universidad Católica del Perú (PE)
Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica, Pontificia Universidad Católica del Perú
Openalex Percentile: Top 24%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.