Impact of occupancy assumptions in international building codes and standards on building performance and energy conservation measures

Building performance simulation (BPS) is an established method for informing building design and demonstrating compliance with building codes and certification programs. However, the accuracy of BPS models depends heavily on occupancy assumptions, which vary significantly across building codes and standards. This paper synthesizes and quantifies the impact of occupancy-related assumptions across 14 international building energy codes and standards on predicted building performance across different climates, covering energy, carbon, and comfort metrics. Four occupancy-based energy conservation measures (ECMs) are then evaluated to study their impact under the different occupancy assumptions: (i) occupancy-based lighting control, (ii) occupancy-based plug loads, (iii) occupancy-based temperature setpoints, and (iv) demand-controlled ventilation (DCV). An application to Canadian office-building archetypes demonstrates that different occupancy assumptions lead to performance variations up to 86% in electricity demand, 60% in natural gas consumption, and 100% in greenhouse gas emissions. Among the tested ECMs, occupancy-based thermostat setpoints significantly reduced peak energy loads and the number of unmet setpoint hours. More importantly, these controls also reduced the sensitivity of building performance to occupancy assumptions, highlighting the importance of aligning heating and cooling loads with actual occupancy patterns to mitigate performance risks. The findings underscore the need for regulators and standard-setting bodies to refine occupancy assumptions in performance-based compliance frameworks and consider a range of plausible occupancy scenarios to improve the reliability of policy outcomes under operational uncertainty. Finally, the study provides an open-access dataset and discusses policy implications.

Authors

Institutions

Publication Details

Journal
Energy Policy
Published
2026-07-25
DOI
https://doi.org/10.1016/j.enpol.2026.115527
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of occupancy assumptions in international building codes and standards on building performance and energy conservation measures

Farzam Kharvari, H. Burak Gunay, Elin Markarian, William O’Brien et al.
Energy Policy
Building Energy and Comfort Optimization
article

Impact of occupancy assumptions in international building codes and standards on building performance and energy conservation measures

Farzam Kharvari, H. Burak Gunay, Elin Markarian, William O’Brien, Elie Azar
article en

Abstract

Building performance simulation (BPS) is an established method for informing building design and demonstrating compliance with building codes and certification programs. However, the accuracy of BPS models depends heavily on occupancy assumptions, which vary significantly across building codes and standards. This paper synthesizes and quantifies the impact of occupancy-related assumptions across 14 international building energy codes and standards on predicted building performance across different climates, covering energy, carbon, and comfort metrics. Four occupancy-based energy conservation measures (ECMs) are then evaluated to study their impact under the different occupancy assumptions: (i) occupancy-based lighting control, (ii) occupancy-based plug loads, (iii) occupancy-based temperature setpoints, and (iv) demand-controlled ventilation (DCV). An application to Canadian office-building archetypes demonstrates that different occupancy assumptions lead to performance variations up to 86% in electricity demand, 60% in natural gas consumption, and 100% in greenhouse gas emissions. Among the tested ECMs, occupancy-based thermostat setpoints significantly reduced peak energy loads and the number of unmet setpoint hours. More importantly, these controls also reduced the sensitivity of building performance to occupancy assumptions, highlighting the importance of aligning heating and cooling loads with actual occupancy patterns to mitigate performance risks. The findings underscore the need for regulators and standard-setting bodies to refine occupancy assumptions in performance-based compliance frameworks and consider a range of plausible occupancy scenarios to improve the reliability of policy outcomes under operational uncertainty. Finally, the study provides an open-access dataset and discusses policy implications.

Energy PolicyVol. 218
Carleton University (CA)
Canada Research Chairs, National Research Council Canada
Openalex Percentile: Top 11%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.