Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations

BACKGROUND: Cuffless blood pressure (BP) monitoring remains challenging for clinical hypertension management. Although photoplethysmography offers promising solutions for cuffless BP measurement, its clinical validation is limited. This study evaluated the accuracy and clinical utility of photoplethysmography-based finger cuffless BP monitoring following European Society of Hypertension recommendations. METHODS: The 2-phase study enrolled 1173 participants. In phase 1 (n=768), a novel photoplethysmography-based finger cuffless BP monitor was validated against invasive BP, office BP, and 24-hour ambulatory BP monitoring across 7 European Society of Hypertension-recommended scenarios. In phase 2 (n=405 hypertensive patients), the clinical utility of photoplethysmography- versus ambulatory BP monitoring-derived mean systolic BP (SBP), SBP time-in-target range, and variability was assessed by examining their associations with hypertension-mediated organ damage and cardiovascular complications, including arterial stiffness, endothelial dysfunction, coronary heart disease, and stroke. RESULTS: The photoplethysmography-based finger cuffless BP monitor fulfilled all validation criteria, with mean differences ≤5 mm Hg and standard deviations ≤8 mm Hg of both systolic and diastolic BP across 7 scenarios, including invasive, static, awake/asleep, device position, treatment, exercise, and recalibration test. Both ambulatory BP monitoring-derived time-in-target range and photoplethysmography-derived mean SBP and time-in-target range were significantly associated with endothelial injury and arterial stiffness. Notably, photoplethysmography-derived mean SBP and time-in-target range, but not ambulatory BP monitoring-derived metrics, showed a significant association with coronary artery disease. Furthermore, photoplethysmography-derived SBP variability was significantly and positively associated with endothelial injury. CONCLUSIONS: Our data demonstrated that the novel photoplethysmography-based finger cuffless BP monitor reached the criteria of clinical application following European Society of Hypertension recommendations and provided additional clinical implications for the evaluation of hypertension-mediated organ damage and cardiovascular complications.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-07-25
DOI
https://doi.org/10.1161/jaha.126.050501
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations

Wenhao Xia, Yumin Qiu, S S Chen, Jun Tao et al.
Journal of the American Heart Association
Non-Invasive Vital Sign Monitoring
article

Clinical Validation of Photoplethysmography‐Based Finger Cuffless Blood Pressure Monitoring Following European Society of Hypertension Recommendations

Wenhao Xia, Yumin Qiu, S S Chen, Jun Tao, Jiang He, Xi Zhang, Shiyue Xu, Jianning Zhang, Zhe Zhou, Ruochen Sun
article en

Abstract

BACKGROUND: Cuffless blood pressure (BP) monitoring remains challenging for clinical hypertension management. Although photoplethysmography offers promising solutions for cuffless BP measurement, its clinical validation is limited. This study evaluated the accuracy and clinical utility of photoplethysmography-based finger cuffless BP monitoring following European Society of Hypertension recommendations. METHODS: The 2-phase study enrolled 1173 participants. In phase 1 (n=768), a novel photoplethysmography-based finger cuffless BP monitor was validated against invasive BP, office BP, and 24-hour ambulatory BP monitoring across 7 European Society of Hypertension-recommended scenarios. In phase 2 (n=405 hypertensive patients), the clinical utility of photoplethysmography- versus ambulatory BP monitoring-derived mean systolic BP (SBP), SBP time-in-target range, and variability was assessed by examining their associations with hypertension-mediated organ damage and cardiovascular complications, including arterial stiffness, endothelial dysfunction, coronary heart disease, and stroke. RESULTS: The photoplethysmography-based finger cuffless BP monitor fulfilled all validation criteria, with mean differences ≤5 mm Hg and standard deviations ≤8 mm Hg of both systolic and diastolic BP across 7 scenarios, including invasive, static, awake/asleep, device position, treatment, exercise, and recalibration test. Both ambulatory BP monitoring-derived time-in-target range and photoplethysmography-derived mean SBP and time-in-target range were significantly associated with endothelial injury and arterial stiffness. Notably, photoplethysmography-derived mean SBP and time-in-target range, but not ambulatory BP monitoring-derived metrics, showed a significant association with coronary artery disease. Furthermore, photoplethysmography-derived SBP variability was significantly and positively associated with endothelial injury. CONCLUSIONS: Our data demonstrated that the novel photoplethysmography-based finger cuffless BP monitor reached the criteria of clinical application following European Society of Hypertension recommendations and provided additional clinical implications for the evaluation of hypertension-mediated organ damage and cardiovascular complications.

Journal of the American Heart Association
Sun Yat-sen University (CN), National Health and Family Planning Commission (CN), The First Affiliated Hospital, Sun Yat-sen University (CN), New York University Langone Orthopedic Hospital (US)
Good health and well-being
Openalex Percentile: Top 16%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.