<scp>1D</scp> Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord

PURPOSE: In the spinal cord (SC), multi-echo gradient echo (ME-GRE) increases gray (GM) and white matter (WM) contrast and improves sensitivity to lesions in people with multiple sclerosis (pwMS). However, SC ME-GRE is susceptible to breathing-induced field fluctuations, causing ghosting artifacts and signal loss. Recent work introduced a 1D phase navigator following the last echo to measure field variations; however, susceptibility to phase wrapping increases at longer echo times. We propose a 1D phase navigator preceding the first echo, reducing phase accumulation and eliminating the need for respiratory monitoring. METHODS: ME-GRE data covering the lower (T9-T12 vertebrae) and upper (T4-T8 vertebrae) thoracic SC were acquired in 20 healthy volunteers and 3 pwMS at 3T. Standard and navigator-corrected images were acquired in the same acquisition. To evaluate image quality, WM and GM signal-to-noise ratio (SNR), WM/GM contrast-to-noise ratio (CNR), and background ghosting signals were measured and compared between the two reconstructions. Both were blindly assessed for artifacts, structural delineation, and diagnostic confidence in pwMS. RESULTS: Navigator correction significantly increased GM and WM SNR and CNR, reduced posterior ghosting across both thoracic regions, and significantly reduced artifacts while increasing structural delineation. Preliminary evaluation in three pwMS showed consistent improvements in artifact mitigation, structural delineation, and lesion conspicuity with navigator correction, providing proof-of-concept for potential clinical application. CONCLUSION: A 1D navigator prior to the first echo reduces ghosting and improves thoracic SC image quality without respiratory monitoring. This approach could improve the diagnostic value and enhance the reliability of thoracic SC ME-GRE.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-07-24
DOI
https://doi.org/10.1002/mrm.70528
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord

Alicia E. Cronin, Ryan K. Robison, Seth Stubblefield, Lipika Narisetti et al.
Magnetic Resonance in Medicine
Ultrasound Imaging and Elastography
article

1D Pre‐Acquisition Navigator Correcting Respiratory‐Induced Field Fluctuations in Multi‐Echo Gradient‐Echo Imaging of the Thoracic Spinal Cord

Alicia E. Cronin, Ryan K. Robison, Seth Stubblefield, Lipika Narisetti, Kristin P. O’Grady, Alexandre D’Astous, Guillaume Gilbert, Seth A. Smith, Antoine Guénette, Colin D. Mcknight, Aimee Salakhov, Nathan Williams, Subramaniam Sriram, Julien Cohen‐Adad
article en

Abstract

PURPOSE: In the spinal cord (SC), multi-echo gradient echo (ME-GRE) increases gray (GM) and white matter (WM) contrast and improves sensitivity to lesions in people with multiple sclerosis (pwMS). However, SC ME-GRE is susceptible to breathing-induced field fluctuations, causing ghosting artifacts and signal loss. Recent work introduced a 1D phase navigator following the last echo to measure field variations; however, susceptibility to phase wrapping increases at longer echo times. We propose a 1D phase navigator preceding the first echo, reducing phase accumulation and eliminating the need for respiratory monitoring. METHODS: ME-GRE data covering the lower (T9-T12 vertebrae) and upper (T4-T8 vertebrae) thoracic SC were acquired in 20 healthy volunteers and 3 pwMS at 3T. Standard and navigator-corrected images were acquired in the same acquisition. To evaluate image quality, WM and GM signal-to-noise ratio (SNR), WM/GM contrast-to-noise ratio (CNR), and background ghosting signals were measured and compared between the two reconstructions. Both were blindly assessed for artifacts, structural delineation, and diagnostic confidence in pwMS. RESULTS: Navigator correction significantly increased GM and WM SNR and CNR, reduced posterior ghosting across both thoracic regions, and significantly reduced artifacts while increasing structural delineation. Preliminary evaluation in three pwMS showed consistent improvements in artifact mitigation, structural delineation, and lesion conspicuity with navigator correction, providing proof-of-concept for potential clinical application. CONCLUSION: A 1D navigator prior to the first echo reduces ghosting and improves thoracic SC image quality without respiratory monitoring. This approach could improve the diagnostic value and enhance the reliability of thoracic SC ME-GRE.

Magnetic Resonance in Medicine
Philips (Finland) (FI), Vanderbilt University (US), Centre Hospitalier Universitaire Sainte-Justine (CA), CARE Canada (CA), Philips (United States) (US), Mila - Quebec Artificial Intelligence Institute (CA), Polytechnique Montréal (CA), Université de Montréal (CA), Vanderbilt University Medical Center (US)
Openalex Percentile: Top 8%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.