CATEGORICAL DECISION CONCORDANCE BETWEEN AN AI ENDOMETRIAL-ASSESSMENT PLATFORM AND EXPERT CLINICIANS AT THE 7-MM TRANSFER-READINESS THRESHOLD: A SECONDARY ANALYSIS OF A 2D

Objective: Building on previously reported continuous-measurement performance of an AI-based endometrial assessment platform (ENDOSCAN) versus expert clinicians [1,2], this work evaluates the clinically decisive question that those analyses did not address: categorical decision agreement between AI and clinicians at the 7-mm endometrial-thickness cutoff used for embryo transfer (ET) readiness, benchmarked against inter-clinician agreement on the same cases. Design: Multicentre, retrospective, comparative-accuracy study with paired AI and human reference measurements. Materials and Methods: Two parallel datasets previously described by our group [1,2] were re-analysed for categorical decision concordance: (i) >150 sagittal 2D ultrasound video clips of the endometrium curated from IVF cycles in Poland and the United States, and (ii) a paired 3D ultrasound dataset acquired in mid-luteal or late-follicular phase. The underlying 2D and 3D deep-learning models a thickest-segment localiser and a 3D convolutional segmentation network benchmarked against manual VOCAL have been reported previously and are not the subject of this submission. In the present analysis, each 2D measurement was dichotomised at the 7-mm transfer-readiness cutoff and categorical agreement was quantified using Cohen’s κ for two pairings: (a) AI versus the reference clinician, and (b) independent clinician versus clinician on the same cases (inter-rater benchmark). Continuous-measurement metrics (ICC, MAE, Bland-Altman) and processing time are restated from the prior reports as context. The pre-specified equivalence claim was that AI-clinician κ would not be lower than clinician–clinician κ. Results: At the 7-mm transfer-readiness cutoff, AI-versus-clinician categorical agreement was Cohen’s κ=0.82 (substantial), equalling or exceeding clinician-to-clinician κ=0.78 on the same cases i.e., AI classifications are no more divergent from expert judgement than experts are from one another. The pre-specified equivalence criterion (AI-clinician κ not inferior to clinician–clinician κ) was therefore met. For context, the continuous-measurement performance underpinning these classifications, reported previously [1,2], was: 2D thickness MAE 1.1 mm and ICC 0.94 versus clinicians; 3D volume ICC 0.93 versus VOCAL with processing time reduced from several minutes to <2 seconds. Performance was preserved across clinics and ultrasound platforms. Conclusions: Beyond the continuous-measurement accuracy demonstrated in our prior work, AI-assisted endometrial assessment achieves expert-level categorical decision agreement at the 7-mm transfer-readiness cutoff, with AI-clinician concordance no worse than clinician-clinician concordance on the same cases. This is the clinically operative outcome for FET decision-making and the principal new contribution of the present analysis. Standardising endometrial evaluation in this way may reduce variability in transfer-readiness decisions and support evidence-based optimisation of FET protocols. Support: MIM Fertility, Warsaw, Poland. All authors are employees/co-owners of MIM Fertility. Software is currently Research Use Only. No external funding. Prior dissemination: components of the underlying AI performance data were previously presented [1,2]; the continuous-measurement metrics (MAE, ICC, processing time) cited above are restated from those communications for context. The categorical threshold-agreement analysis (Cohen’s κ at the 7-mm cutoff, with clinician–clinician benchmark) presented here has not been previously reported.

Authors

Institutions

Publication Details

Journal
North American Proceedings in Gynecology and Obstetrics - Supplemental
Published
2026-07-25
DOI
https://doi.org/10.54053/001c.165564
Primary Topic
Ovarian function and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CATEGORICAL DECISION CONCORDANCE BETWEEN AN AI ENDOMETRIAL-ASSESSMENT PLATFORM AND EXPERT CLINICIANS AT THE 7-MM TRANSFER-READINESS THRESHOLD: A SECONDARY ANALYSIS OF A 2D

U Sankowska, P Pierzyński, A Zapala, P Pawlik et al.
North American Proceedings in Gynecology and Obstetrics - Supplemental
Ovarian function and disorders
article

CATEGORICAL DECISION CONCORDANCE BETWEEN AN AI ENDOMETRIAL-ASSESSMENT PLATFORM AND EXPERT CLINICIANS AT THE 7-MM TRANSFER-READINESS THRESHOLD: A SECONDARY ANALYSIS OF A 2D

U Sankowska, P Pierzyński, A Zapala, P Pawlik, B Tralik, J Zak, P Wygocki, M Siennicki, K Pankiewicz
article en

Abstract

Objective: Building on previously reported continuous-measurement performance of an AI-based endometrial assessment platform (ENDOSCAN) versus expert clinicians [1,2], this work evaluates the clinically decisive question that those analyses did not address: categorical decision agreement between AI and clinicians at the 7-mm endometrial-thickness cutoff used for embryo transfer (ET) readiness, benchmarked against inter-clinician agreement on the same cases. Design: Multicentre, retrospective, comparative-accuracy study with paired AI and human reference measurements. Materials and Methods: Two parallel datasets previously described by our group [1,2] were re-analysed for categorical decision concordance: (i) >150 sagittal 2D ultrasound video clips of the endometrium curated from IVF cycles in Poland and the United States, and (ii) a paired 3D ultrasound dataset acquired in mid-luteal or late-follicular phase. The underlying 2D and 3D deep-learning models a thickest-segment localiser and a 3D convolutional segmentation network benchmarked against manual VOCAL have been reported previously and are not the subject of this submission. In the present analysis, each 2D measurement was dichotomised at the 7-mm transfer-readiness cutoff and categorical agreement was quantified using Cohen’s κ for two pairings: (a) AI versus the reference clinician, and (b) independent clinician versus clinician on the same cases (inter-rater benchmark). Continuous-measurement metrics (ICC, MAE, Bland-Altman) and processing time are restated from the prior reports as context. The pre-specified equivalence claim was that AI-clinician κ would not be lower than clinician–clinician κ. Results: At the 7-mm transfer-readiness cutoff, AI-versus-clinician categorical agreement was Cohen’s κ=0.82 (substantial), equalling or exceeding clinician-to-clinician κ=0.78 on the same cases i.e., AI classifications are no more divergent from expert judgement than experts are from one another. The pre-specified equivalence criterion (AI-clinician κ not inferior to clinician–clinician κ) was therefore met. For context, the continuous-measurement performance underpinning these classifications, reported previously [1,2], was: 2D thickness MAE 1.1 mm and ICC 0.94 versus clinicians; 3D volume ICC 0.93 versus VOCAL with processing time reduced from several minutes to <2 seconds. Performance was preserved across clinics and ultrasound platforms. Conclusions: Beyond the continuous-measurement accuracy demonstrated in our prior work, AI-assisted endometrial assessment achieves expert-level categorical decision agreement at the 7-mm transfer-readiness cutoff, with AI-clinician concordance no worse than clinician-clinician concordance on the same cases. This is the clinically operative outcome for FET decision-making and the principal new contribution of the present analysis. Standardising endometrial evaluation in this way may reduce variability in transfer-readiness decisions and support evidence-based optimisation of FET protocols. Support: MIM Fertility, Warsaw, Poland. All authors are employees/co-owners of MIM Fertility. Software is currently Research Use Only. No external funding. Prior dissemination: components of the underlying AI performance data were previously presented [1,2]; the continuous-measurement metrics (MAE, ICC, processing time) cited above are restated from those communications for context. The categorical threshold-agreement analysis (Cohen’s κ at the 7-mm cutoff, with clinician–clinician benchmark) presented here has not been previously reported.

North American Proceedings in Gynecology and Obstetrics - SupplementalVol. Suppl(MRSi)
AMPAC Fine Chemicals (United States) (US), University of Warsaw (PL)
Peace, Justice and strong institutions
Openalex Percentile: Top 7%
Ovarian function and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.