Accuracy of artificial intelligence-based detection of dental crowding and spacing on cone-beam computed tomography

Abstract Background To evaluate the accuracy of an artificial intelligence (AI) system for detecting anterior dental crowding and spacing on cone-beam computed tomography (CBCT) and to characterise clinically relevant patterns of diagnostic failure. Methods In this retrospective diagnostic accuracy study, CBCT scans from 88 patients were analysed. AI-generated diagnoses at the tooth-pair level were compared with a reference standard based on a modified Little’s Irregularity Index (mLII) that incorporates signed contact-point displacement. Diagnostic performance — sensitivity, specificity, positive and negative predictive values, and Cohen’s κ — was assessed at the tooth-pair level ( n = 875) across five thresholds (± 0.5 to ± 2.5 mm). Arch-level performance was assessed using the conventional Little’s Irregularity Index (LII). Statistical significance was set at α = 0.05, and all estimates are reported with 95% confidence intervals. Results At the tooth-pair level, sensitivity for crowding ranged from 28.8% to 42.0%, whereas specificity remained high (81.9–88.9%). Agreement with the reference standard was fair (maximum κ = 0.247). A consistent blind spot was identified at the maxillary central-incisor pair (11–21), where no crowded cases were detected despite confirmed irregularities. Spacing detection was poor (sensitivity 10–25%). At the arch level, detection improved with increasing severity of irregularity (38.8–75.0%) but remained incomplete and was accompanied by a high false-positive rate (41.2% in perfectly aligned arches). Conclusions The AI system showed limited sensitivity and only fair agreement for detecting anterior crowding and spacing on CBCT. Clinically relevant irregularities, including those at the anterior midline, may be missed. Because crowding and spacing are most reliably assessed from clinical examination and intraoral records rather than from CBCT, AI-based CBCT assessments should be interpreted with caution and cannot replace clinician evaluation.

Authors

Institutions

Publication Details

Journal
BMC Oral Health
Published
2026-07-25
DOI
https://doi.org/10.1186/s12903-026-09405-0
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of artificial intelligence-based detection of dental crowding and spacing on cone-beam computed tomography

Emilia Czarnecka, Emilia Zielińska, Tomasz Kulczyk, Agnieszka Jankowska et al.
BMC Oral Health
Dental Radiography and Imaging
article

Accuracy of artificial intelligence-based detection of dental crowding and spacing on cone-beam computed tomography

Emilia Czarnecka, Emilia Zielińska, Tomasz Kulczyk, Agnieszka Jankowska, Tomasz Jankowski, Wojciech Kazimierczak, Natalia Kazimierczak, Zbigniew Serafin, Małgorzata Dittrich, Łukasz Wanczura, Wiktoria Biegała
article en

Abstract

Abstract Background To evaluate the accuracy of an artificial intelligence (AI) system for detecting anterior dental crowding and spacing on cone-beam computed tomography (CBCT) and to characterise clinically relevant patterns of diagnostic failure. Methods In this retrospective diagnostic accuracy study, CBCT scans from 88 patients were analysed. AI-generated diagnoses at the tooth-pair level were compared with a reference standard based on a modified Little’s Irregularity Index (mLII) that incorporates signed contact-point displacement. Diagnostic performance — sensitivity, specificity, positive and negative predictive values, and Cohen’s κ — was assessed at the tooth-pair level ( n = 875) across five thresholds (± 0.5 to ± 2.5 mm). Arch-level performance was assessed using the conventional Little’s Irregularity Index (LII). Statistical significance was set at α = 0.05, and all estimates are reported with 95% confidence intervals. Results At the tooth-pair level, sensitivity for crowding ranged from 28.8% to 42.0%, whereas specificity remained high (81.9–88.9%). Agreement with the reference standard was fair (maximum κ = 0.247). A consistent blind spot was identified at the maxillary central-incisor pair (11–21), where no crowded cases were detected despite confirmed irregularities. Spacing detection was poor (sensitivity 10–25%). At the arch level, detection improved with increasing severity of irregularity (38.8–75.0%) but remained incomplete and was accompanied by a high false-positive rate (41.2% in perfectly aligned arches). Conclusions The AI system showed limited sensitivity and only fair agreement for detecting anterior crowding and spacing on CBCT. Clinically relevant irregularities, including those at the anterior midline, may be missed. Because crowding and spacing are most reliably assessed from clinical examination and intraoral records rather than from CBCT, AI-based CBCT assessments should be interpreted with caution and cannot replace clinician evaluation.

BMC Oral Health
Poznan University of Medical Sciences (PL), Jan Długosz University (PL), Bydgoszcz University of Science and Technology (PL), Kazimierz Wielki University in Bydgoszcz (PL), Nicolaus Copernicus University (PL), AGH University of Krakow (PL)
No poverty
Openalex Percentile: Top 7%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.