Towards reliable long-term environmental odour monitoring with electronic noses: compensation of humidity and sensor drift effects

Implementation of electronic noses at the fenceline of industrial plants is becoming relevant in order to monitor odour emissions from these facilities. Literature studies proved the applicability of these instruments for this purpose; however, their application over long period of time is hindered by the presence of interferences. We propose the application of two pre-processing strategies to compensate the presence of humidity variations and sensor drift, two interferents commonly found in uncontrolled sampling systems. We validated the methodology on two electronic noses installed at the fenceline of a waste treatment plant during 16 months. Different classification models have been developed based on different data pre-treatment and their performance was evaluated through field performance testing. Results show that the implemented methodology effectively reduces drift effects and improves classification accuracy for different odour sources, enhancing the feasibility of these instruments for industrial odour monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Management
Published
2026-07-25
DOI
https://doi.org/10.1016/j.jenvman.2026.130512
Primary Topic
Odor and Emission Control Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards reliable long-term environmental odour monitoring with electronic noses: compensation of humidity and sensor drift effects

Laura Capelli, Jordi Fonollosa, Christian Ratti, Andreas Cardona
Journal of Environmental Management
Odor and Emission Control Technologies
article

Towards reliable long-term environmental odour monitoring with electronic noses: compensation of humidity and sensor drift effects

Laura Capelli, Jordi Fonollosa, Christian Ratti, Andreas Cardona
article en

Abstract

Implementation of electronic noses at the fenceline of industrial plants is becoming relevant in order to monitor odour emissions from these facilities. Literature studies proved the applicability of these instruments for this purpose; however, their application over long period of time is hindered by the presence of interferences. We propose the application of two pre-processing strategies to compensate the presence of humidity variations and sensor drift, two interferents commonly found in uncontrolled sampling systems. We validated the methodology on two electronic noses installed at the fenceline of a waste treatment plant during 16 months. Different classification models have been developed based on different data pre-treatment and their performance was evaluated through field performance testing. Results show that the implemented methodology effectively reduces drift effects and improves classification accuracy for different odour sources, enhancing the feasibility of these instruments for industrial odour monitoring.

Journal of Environmental ManagementVol. 414
Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES), Sant Joan de Déu Research Foundation (ES), Institut de Recerca Sant Joan de Déu, Politecnico di Milano (IT), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 20%
Odor and Emission Control Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.